Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94624)
(54)
(575)
(124)
(33)
(21)
(20)
(94991)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ICC
    International Residential Code, 3rd Printing
    Edition: 2021
    $254.13
    / user per year

Content Description

This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical requirements for one- and two-family dwellings and townhouses up to three stories. The 2021 IRC® contains many important changes such as: Braced wall lines must be placed on a physical wall or placed between multiple walls. The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units. Emergency escape and rescue openings require a clear 36-inch-wide path to a public way. An engineered design is required for storm shelters. A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers. Updated Wind Speed maps match IBC and ASCE 7 maps. Deck design now considers snow load, tributary area for footing and post height, and guard details. Specific requirements for deck guardrails were added. Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles. Minimum footing size tables are revised to more accurately reflect current practice. Cripple wall requirements apply only to exterior cripple walls. New appendices for cob construction and 3D printed construction are added. A 30 percent reduction of airflow is permitted for balanced ventilation systems. Commercial gas cooking appliances are prohibited. The head pressure for a water test of DWV systems increased to 10 feet. Air vacuum testing is now permitted for plastic piping DWV systems. Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D. An emergency service disconnect is required in a readily accessible outdoor location. A surge-protective device (SPD) is now required at the service panel. The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface. GFCI protection is now required for damp and wet locations not included in the other 10 areas requiring GFCI protection.
X
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50
51 52 53 54 55 56 57 58 59 60
61 62 63 64 65 66 67 68 69 70
71 72 73 74 75 76 77 78 79 80
81 82 83 84 85 86 87 88 89 90
91 92 93 94 95 96 97 98 99 100