Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94624)
(54)
(575)
(124)
(33)
(21)
(20)
(94991)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    CP 102:1973 Code of practice for protection of buildings against water from the ground
    Edition: 1973
    $442.60
    / user per year

Description of CP 102:1973 1973

This Code deals with the methods of preventing the entry of ground water and surface water into a building from the surrounding areas. It makes recommendations for the drainage of adjoining areas, for special waterproof or water-resisting types of construction below ground level and for the damp-proofing of walls and floors at or near ground level.

It has been assumed that the design of all constructional work within the scope of this Code will be carried out by an architect and/or engineer experienced in the type of construction concerned and referred to throughout this Code as the designer.

Section 2 of this Code describes methods of preventing the entry of ground water into a building at or below ground level where ground or surface water may not be able to escape immediately.

Section 3 of this Code describes methods of providing damp-proofing of walls and floors at or near ground level.

In Section 2 two types of structure are considered:

  1. Type A in which protection is provided by a continuous impervious membrane which excludes visible penetration of water and provides a vapour seal.

  2. Type B in which visible penetration of water is prevented, but transmission in the form of vapour may not be wholly excluded. For the purposes of this Code, this degree of protection is assumed to be provided by high quality reinforced or prestressed concrete.

No recommendations are included in this Code for the use of embedded heating in basements, floors and wall or for the special requirements in connection with the design and construction of cold-stores.

NOTE The titles of the British Standards referred to in this Code are listed on page 26.



Gives methods of preventing entry of ground and surface water into the building from surrounding areas. Section 2 describes methods of prevention at or below ground floor level, section 3 deals with methods of providing damp-proofing of walls and floors at ground level by use of d.p.c. materials to BS 743.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X