FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN ISO 15883-1:2009+A1:2014 20142 Normative references (modified) The normative references have been updated to reflect current editions of standards and standards that have replaced ones previously listed. Note in particular the inclusion of IEC 61010‑2‑040:2005, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials (see commentary on Clause 5). 3 Terms and definitions (modified) A number of minor changes have been made to the definitions to harmonize these with other standards. These include the definitions of bioburden (3.4) and D value (3.14). 5 Mechanical and process requirements (modified) In the 2006 version of the washer-disinfector (WD) standard under Clause 5 Mechanical and Process Requirements, the safety requirements specified compliance to an older standard, IEC 61010-2-045, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-045: Particular requirements for washer disinfectors used in medical, pharmaceutical, veterinary and laboratory fields. This standard has since been withdrawn and is now replaced by IEC 61010‑2‑040:2005. In general, the working groups of CEN TC102 (including WG8) have decided to defer to IEC 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements) and IEC 61010-2-040 as the basic standards regarding safety issues. EN 60601-1:2006+A1:2013 was recently updated and published. At the time of this report, the IEC 61010-2-040 standard is currently under revision by IEC TC66 Safety of measuring, control and laboratory equipment, in liaison with CEN TC 102. A further safety requirement included in this update is regarding electromagnetic compatibility (EMC) and specifically requires compliance with IEC 61326‑1:2006, Electrical equipment for measurement, control and laboratory use — EMC requirements —Part 1: General requirements. WDs that are designed to operate in areas with medical electrical equipment or in the vicinity of other sensitive equipment are now regarded as class B equipment as specified in IEC 61326‑1. It is important to note that compliance with these referenced standards may not be assumed to meet all the safety aspects of WD design and specifically the EU Machinery Directive 2006/42/EC. Therefore, the standard amendments also require risk analysis and management to be considered for WD design, including associated software. The standard specifically requires risks to be managed in compliance with ISO 14971, Medical devices - Application of risk management to medical devices. This is a major change and specifically highlights the need to consider aspects such as ease of use, ergonomics and the knowledge, experience and training of those intending to operate the WD. 5.20 Microprocessor control systems (modified) The design criteria for any associated microprocessor control systems now include an additional requirement for the associated software to be validated. 8.3 At delivery of the WD (modified) There are two new requirements for information to be provided by the manufacturer to the purchaser of the WD. These are to provide:
Annex ZA (modified) The informative Annex ZA on the relationship between the published European Standard and the essential requirements of the EU Directive 93/42/EEC on medical devices (Table ZA.1) and EU Directive 2006/42/EC on machinery (Table ZA.2) has been updated. This Annex can be useful in verifying the presumption of conformity to the Directives, but it is important to note that other requirements or even other EU Directives may be applicable to the specific WD. Bibliography (modified) The bibliography has been updated to include current editions of relevant standards and applicable references.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|