FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN IEC 60598-1:2024 - TC 2025IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document. This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new structure to comply with the ISO/IEC Directives, Part 2; b) addition of a new Annex V for comparison with the previous edition; c) revision of 7.32 for SPDs and for SPCs; d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195; e) revision of 7.14.2 for conductor mechanical stress; f) revision of 14.5.2, Item 4 to include controlgear; g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently"; h) revision of Annex N: earth continuity test time; i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets; j) addition of a new Annex W for luminaires using batteries; k) clarification of Clause 6 for marking requirements for nature of supply; l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s); m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA; n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components; o) revision of Annex D: Draught-proof enclosure; p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges; q) revision of 9.2.10 for looping-in; r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 61058Â2Â1. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1; s) revision of 6.3.22 and 7.24 for photobiological safety; t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|