FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN IEC 60335-2-40:2023+A11:2023 2023IEC 60335-2-40:2018 is available as IEC 60335-2-40:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60335-2-40:2018 deals with the safety of electric heat pumps, including sanitary hot water heat pumps, air conditioners, and dehumidifiers incorporating motor-compressors and hydronic fan coils units, their maximum rated voltages being not more than 250 V for single phase appliances and 600 V for all other appliances. Partial units are within the scope of this International Standard. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. The appliances referenced above may consist of one or more factory-made assemblies. If provided in more than one assembly, the separate assemblies are to be used together, and the requirements are based on the use of matched assemblies. This standard does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817 classification, A2L refrigerants are limited to those of a molar mass of more than or equal to 42 kg/kmol based on WCF – Worst Case Formulation as specified in ISO 817. This standard specifies particular requirements for the use of flammable refrigerants. Unless specifications are covered by this standard, including the annexes, requirements for refrigerating safety are covered by ISO 5149. Supplementary heaters, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance. For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; for appliances subjected to pressure, additional requirements may be necessary; This standard does not apply to: humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88); appliances designed exclusively for industrial processing or appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas). This sixth edition cancels and replaces the fifth edition published in 2013 and its Amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clause 1 – limiting A2L refrigerants to those of a molar mass of more than or equal to 42 kg/kmol; - Clause 7 – added requirements for A2L refrigerants, - Clause 7 – added requirement for pre-charge pipe sets, detection systems, ventilation and the resulting charge; - Clause 7 – added requirements for UV-C systems; - Clause 7 – added requirements for transcritical refrigerating systems; - Subclause 19.7 – amended text to match the intention of the subclause; - Clause 21 – added requirements for transcritical refrigerating systems; - Subclause 22 – added requirements for A2L refrigerants; - Subclause 22– added detection systems; - Subclause 22 – added new requirements for enhanced tightness refrigerating systems; - Subclause 22 – added new requirements for UV-C; - Clause 23 – added new requirements for UV-C;Clause - Clause 24 – added requirements for transcritical refrigerating systems; - Subclause 24 – added requirements for detection systems and airflow; - Clause 32 added new requirements for UV-C; - Annex BB – revised to add surface temperatures; - Annex DD – added requirements for A2L refrigerants and amended requirements for flammable refrigerants to exempt A2L refrigerants; - Annex GG – added requirements for A2L refrigerants; - Annex GG.1 – amended Table GG.1 and related wording - Annex GG.7 – added requirement to test; - Annex GG.8 to GG.13 – new coverage for A2L refrigerants; - Annex HH – revised to take into account A2L refrigerants; - Annex JJ – new coverage of allowable opening of relays and similar components to prevent ignition of A2L refrigerants; - Annex KK – new coverage of test method for hot surface ignition temperature for A2L; - Annex LL – new coverage of refrigerant detection systems for A2L Refrigerants; - Annex MM – new coverage of refrigerant sensor location confirmation test; - Annex NN – new coverage of flame arrest enclosure verification test for A2L refrigerants; - Annex OO – new coverage of UV radiation conditioning - Bibliography – added new references. This part 2-40 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of IEC 60335-1:2010, its Amendment 1:2013 and its Amendment 2:2016.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|