FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 61558-2-16:2009+A1:2013 2014Replacement: This part of IEC 61558 deals with the safety of switch mode power supply units and transformers for switch mode power supply units. Transformers incorporating electronic circuits are also covered by this standard.
This part applies to:
This part covers the safety requirements for:
For SMPS for specific application corresponding to the other Parts 2 of 61558 series, the necessary requirements of the relevant Parts 2 are applicable. In addition, the requirements listed in this part apply. Where the two requirements are in conflict, the most severe take precedence.
Switch mode power supply units covered by this standard are air cooled (natural or forced) independent, associated, stationary, portable, single-phase, or polyphase, with the rated supply voltage not exceeding 1 100 V a.c., the rated supply frequency not exceeding 500 Hz, the rated internal operating frequency exceeding 500 Hz, but not exceeding 100 MHz, and the rated output not exceeding 1 kVA or 1 kW, incorporating dry-type transformers with encapsulated or non-encapsulated windings. Associated transformers for switch mode power supply units covered by Annex BB of this standard shall have a rated output not exceeding:
The no-load output voltage or the rated output voltage of switch mode power supply units shall not exceed:
The no-load output voltage or the rated output voltage of independent switch mode power supply units shall not be less than:
This standard is also applicable to switch mode power supply units, converters and inverters without limitation of the rated output. However, such switch mode power supply units are for special applications and are subject to an agreement between the purchaser and the manufacturer.
This standard may also be used as a guide for products not covered by the scope of this standard, the scope of IEC 61204-7, or the scope of IEC 61347 series. This standard does not apply to:
Unless otherwise specified, from here onward, the term SMPS covers switch mode power supply units.