FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 61010-2-101:2017 - TC 2020IEC 61010-2-101:2015 is available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It constitutes a technical revision and includes the following significant changes from the first edition, as well as numerous other changes: - excluded IEC 61010-2-081 (general laboratory equipment) from the scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment; - updated Biohazard and Lot symbols in Table 1 in Clause 5; - added requirement for within expiration consumables and authorized representative details in Instructions for Use to Clause 5; - added requirement for gas or liquid markings and ratings to Clause 5; - added requirement to include OPERATOR instructions to deal with consumable or sample spills, jams or breakage inside equipment, disposal of hazardous waste, personal protection, RISK reduction procedures relating to flammable liquids, burns from surfaces, and loading and unloading of sample and reagents in Instructions for Use to Clause 5; - added requirement for manufacturer to provide instructions on equipment transport, storage and removal from use to Clause 5; - added normative reference ISO 18113-5 for instructions for use of self-test IVD medical equipment in Clause 5; - added requirement for OPERATOR maintenance instructions to Clause 7; - added requirements for sample zones and loading zones to Clause 7; - excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8; - added requirement for biohazard marking to Clause 13; - added requirement for interlock systems containing electric/electronic or programmable components to Clause 15; - added informative reference to Usability standard IEC 62366 to Clause 16; - replaced Clause 17 with requirements of ISO 14971 for RISK assessment. - Annex BB Instructions for use for self-testing IVD Medical Equipment deleted and a reference given to ISO 18113-5 in Clause 5. This publication is to be read in conjunction with /2.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|