FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 60846-1:2014 2014This part of the IEC 60846 series applies to dose equivalent (rate) meters and/or monitors for the measurement of ambient dose equivalent (rate) and/or directional dose equivalent (rate) from external beta, X and gamma radiation, as recommended in ICRU, Report 47. NOTE 1 If both quantities, ambient dose equivalent and directional dose equivalent are meant, the term dose equivalent may be used as an abbreviation. This part of IEC 60846 series applies only to portable meters and monitors which are intended to be used in both the workplace and the environment. It applies to devices that measure the dose equivalent or dose equivalent rate from external beta and/or X and gamma radiation in the dose range between 0,01 μSv and 10 Sv and the dose rate range between 0,01 μSv h −1 and 10 Sv h −1 and in the energy ranges given in the following Table. All the energy values are mean energies with respect to the prevailing dose quantity. Table 1 Measuring quantities and energy ranges covered by the standard
a For beta-particle radiation, an energy of 0,07Â MeV is required to penetrate the dead layer of skin of 0,07Â mm (almost equivalent to 0,07Â mm of ICRU tissue) nominal depth. NOTEÂ 2 Where a dose rate meter or monitor may be attached to a supplementary probe used to monitor contamination, the relevant standard for that probe is IECÂ 60325 . If national legislation requires the use of different measuring quantities, for example, air kerma or exposure, the standard may be used with the respective adjustments. In this document, the expression "dose equivalent (rate)" is used when the provisions apply to both the measurement of dose equivalent and the measurement of dose equivalent rate. NOTEÂ 3 It does not apply to medical radiology which is within the scope of technical committee 62, where the conditions of radiation exposure may be extremely inhomogeneous, but precisely known. NOTEÂ 4 It does not apply to instruments intended to be worn by an individual for the purpose of estimating the radiation dose received by that individual. The object of this standard is to specify the design requirements and the performance characteristics of dose equivalent (rate) meters intended for the determination of ambient dose equivalent (rate) and directional dose equivalent (rate) as defined in ICRU Report 47. Accordingly, this standard specifies:
Some countries may wish to use this type of dose equivalent (rate) meter for measurements in the framework of legal metrology.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|