Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94624)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN 60601-1-12:2015+A1:2020 Medical electrical equipment - General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
    Edition: 2020
    $526.05
    / user per year

Description of BS EN 60601-1-12:2015+A1:2020 2020

This International Standard applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems, hereafter referred to as me equipment and me systems, which are intended, as indicated in the instructions for use by their manufacturer, for use in the ems environment (emergency medical services environment), as defined in 3.1.

NOTE 1 For the purposes of this standard, the intent of the manufacturer is indicated in the instructions for use. The responsible organization and the operator need to be aware that any other use outside the manufacturer’s intended use can result in a hazardous situation for the patient.

The ems environment includes

  • responding to and providing life support at the scene of an emergency to a patient reported as experiencing injury or illness in a pre-hospital setting, and transporting the patient, while continuing such life support care, to an appropriate professional healthcare facility for further care.

  • providing monitoring, treatment or diagnosis during transport between professional healthcare facilities.

This International Standard does not apply to me equipment and me systems intended solely for use in the home healthcare environment covered by IEC 60601‑1‑11 or solely for use in professional healthcare facilities covered by IEC 60601‑1 without the additions of IEC 60601‑1‑11 or this collateral standard. me equipment and me systems are often not solely intended for one environment. Such me equipment or me system can be intended for multiple use environments, and as such, if also intended for use in the ems environment, are within the scope of this standard.

EXAMPLE

Me equipment or me system intended for both the ems environment and the professional healthcare facility environment.

NOTE 2 Ems environment me equipment and me systems can be used in locations with unreliable electrical sources and outdoor environmental conditions.

1.2 * Object

The object of this collateral standard is to provide general requirements for me equipment and me systems carried to the scene of an emergency and used there, as well as in transport, in situations where the ambient conditions differ from indoor conditions.

The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards.

1.3 Related standards

1.3.1 IEC 60601‑1

A1_startFor me equipment and me systems, this collateral standard complements IEC 60601‑1.A1_end

When referring to IEC 60601‑1 or to this collateral standard, either individually or in combination, the following conventions are used:

  • "the general standard" designates IEC 60601‑1 alone, A1_startincluding any amendmentsA1_end;

  • "this collateral standard" designates IEC 60601‑1‑12 alone, A1_startincluding any amendmentsA1_end;

  • "this standard" designates the combination of the general standard and this collateral standard.

1.3.2 Particular standards

A requirement in a particular standard takes priority over the corresponding requirement in this collateral standard.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X