FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN 13381-10:2020 2020This document specifies a fire test method and an assessment procedure for determining the contribution of fire protection systems to the fire resistance performance of circular and rectangular steel bars used as tension members. This document applies to fire protection materials that have already been tested and assessed in accordance with EN 13381 4 or EN 13381 8. For other section shapes such as angles, channels and flats, reference can be made to EN 13381 4 and EN 13381 8. This document does not include steel or any other cold formed bar used as reinforcement in concrete construction. For other solid bar geometries such as oval or triangular cross section, these are subject to a separate test package in accordance with the principles of Clause 5 of this document. Fire protection performance is determined by testing of unloaded tension members, although additional loaded test evidence can be required for certain product types subject to certain conditions specified in the document. The method is applicable to all fire protection systems used for the protection of solid bar up to a maximum diameter of 130 mm and includes sprayed fire protection, reactive coatings, cladding protection systems and multi-layer or composite fire protection materials. In the case of rectangular bar, the maximum side length is limited to 130 mm with a maximum aspect ratio of 2:1 against the shorter side length. For dimensions greater than 130 mm it is appropriate to use rectangular or circular hollow sections tested and assessed in accordance with EN 13381 4 and EN 13381 8 provided they have been tested The method is applicable to all fire protection systems used for the protection of solid bar up to a maximum diameter of 130 mm and includes sprayed fire protection, reactive coatings, cladding protection systems and multi-layer or composite fire protection materials. In the case of rectangular bar, the maximum side length should be limited to 130mm with a maximum aspect ratio of 2:1 against the shorter side length. For dimensions greater than 130mm it is appropriate to use rectangular or circular hollow sections tested and assessed in accordance with EN 13381 4 and EN 13381 8 provided they have been tested in the same orientation. The evaluation is designed to cover a range of thicknesses of the applied fire protection material, a range of steel bar dimensions, a range of specified temperatures and a range of valid fire protection periods. The test method is applicable to fire protection systems which are intimately in contact with the bar, or which include an airspace between the bar and the protection system as given in EN 13381-4. This standard also provides the assessment procedure, which prescribes the analysis of the test data and gives guidance on the procedures to undertake interpolation. This Standard caters for testing in both vertical and horizontal orientations. Results from horizontally orientated bar may be applied to any orientation, whilst results from vertically orientated bar should only be used for horizontal bars when the data has been corrected in accordance with Annex C. This standard gives the fire test procedures, carried out to provide data on the thermal characteristics of the fire protection system, when exposed to the standard temperature/time curve specified in Clause 5.1.1 of EN 1363 1. The assessment procedure is used to establish: a) on the basis of data derived from testing steel bar, any practical constraints on the use of the fire protection system under fire test conditions (the physical performance); b) on the basis of the temperature data derived from testing steel bar the thermal properties of the fire protection system (the thermal performance). The limits of applicability of the results of the assessment arising from the fire test are defined together with application of the results to different steel types and sizes over the range of thicknesses of the applied fire protection system tested.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|