Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94624)
(54)
(575)
(124)
(33)
(21)
(20)
(94991)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS 4856-2:1975 Methods for testing and rating fan coil units, unit heaters and unit coolers - Thermal and volumetric performance for cooling duties: without additional ducting
    Edition: 1975
    $442.60
    / user per year

Description of BS 4856-2:1975 1975

Part 2 of this British Standard deals with methods of carrying out thermal and volumetric tests of unit coolers without additional ducting. The unit coolers operate with or without condensation on the coils. The unit coolers are of the type used for cooling and dehumidifying purposes under frost-free conditions of operation. The cooling medium used is water or other heat transfer fluid (excluding volatile refrigerants). The range of approximate air volume flow rates is between 25 × 10–3 m3/s and 5 m3/s.

The tests are to be carried out on units in an essentially clean condition.

This standard applies to units having operating temperatures of primary fluid within the range 0 °C to 27 °C.

The primary fluids used are; water, brine, glycol, heat transfer fluid.

The minimum temperature differential (see 14.2) of the primary fluid under test is 3 °C.

There is no restriction on the mounting of these units for testing provided that they are tested whilst mounted in a way representative of their intended use.

The standard specifies performance characteristics that are to be obtained from a unit. Although the requirements of the methods for individual tests may be followed to determine the performance of a unit at one specified set of conditions, where the performance at conditions other than those of the actual test are to be stated the full schedule of tests specified in the standard have to be made.



Coolers as used for cooling and dehumidifying under frost-free conditions, the medium used being water or other heat transfer fluid (excluding volatile refrigerants).