FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of 25/30497190 DC 2025This document specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium profiled sheeting, and for the installation of structural members made of aluminium for roof, ceiling, floor, wall and cladding applications. This document applies to structures designed according to the EN 1999 series. This document applies to profiled sheeting to be designed according to EN 1999 1 4. This document also specifies requirements for the execution i.e. the manufacture and the installation of structures made from cold-formed profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading or seismic loading conditions and their documentation. This document covers products of Structural Class I and II and structural profiled sheeting in Structural Class III according to EN 1999 1 4 used in structures. NOTE 1 In National Annexes of EN 1999 1 4 specifications can be given regarding the use of the Structural Classes. Structural profiled sheeting is understood here to be profiled sheet, such as trapezoidal or sinusoidal (Figure 1). Perforated and micro profiled sheeting are also covered by this part. This document also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements (Figure 2). A combination of steel and aluminium structural profiled sheeting are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090 4 and this document apply. This document also covers the deconstruction of structures made from cold-formed profiled sheeting and structural members for roof, ceiling, floor and wall applications. This document does not cover the manufacturing of structural members of all structural classes according to EN 1999 1 4. These products are covered by EN 1090 3. Welded sections are excluded from this part and are covered by EN 1090 3 except seal welding in low-stress areas. Composite structural profiled sheeting where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE 2 The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural profiled sheeting; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural profiled sheeting; or - suspended ceilings for interior fitting.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|