Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(338)
(589)
(55)
(234)
(996)
(690)
(2161)
(117)
(94958)
(58)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(319)
(6732)
(241)
(16)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    25/30497190 DC BS EN 1090-5 Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications
    Edition: 2025
    $41.58
    / user per year

Description of 25/30497190 DC 2025

This document specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium profiled sheeting, and for the installation of structural members made of aluminium for roof, ceiling, floor, wall and cladding applications. This document applies to structures designed according to the EN 1999 series. This document applies to profiled sheeting to be designed according to EN 1999 1 4. This document also specifies requirements for the execution i.e. the manufacture and the installation of structures made from cold-formed profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading or seismic loading conditions and their documentation. This document covers products of Structural Class I and II and structural profiled sheeting in Structural Class III according to EN 1999 1 4 used in structures. NOTE 1 In National Annexes of EN 1999 1 4 specifications can be given regarding the use of the Structural Classes. Structural profiled sheeting is understood here to be profiled sheet, such as trapezoidal or sinusoidal (Figure 1). Perforated and micro profiled sheeting are also covered by this part. This document also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements (Figure 2). A combination of steel and aluminium structural profiled sheeting are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090 4 and this document apply. This document also covers the deconstruction of structures made from cold-formed profiled sheeting and structural members for roof, ceiling, floor and wall applications. This document does not cover the manufacturing of structural members of all structural classes according to EN 1999 1 4. These products are covered by EN 1090 3. Welded sections are excluded from this part and are covered by EN 1090 3 except seal welding in low-stress areas. Composite structural profiled sheeting where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard. NOTE 2 The structures covered in this standard can be for example - single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural profiled sheeting; - single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural profiled sheeting; or - suspended ceilings for interior fitting.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X