Historical Standard: ASTM F744M-97 Standard Test Method for Measuring Dose Rate Threshold for Upset of Digital Integrated Circuits
SUPERSEDED (see Active link, below)
ASTM F744M
1. Scope
1.1 This test method covers the measurement of the threshold level of radiation dose rate that causes upset in digital integrated circuits under static operating conditions. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).
1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.
1.3 The test may be destructive either for further tests or for purposes other than this test if the integrated circuit being tested absorbs a total radiation dose exceeding some predetermined level. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test (6.9).
1.4 Setup, calibration, and test circuit evaluation procedures are included in this test method.
1.5 Procedures for lot qualification and sampling are not included in this test method.
1.6 Because of the variability of the response of different device types, the initial dose rate for any specific test is not given in this test method but must be agreed upon by the parties to the test.
1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific hazard statements, see 7.7.2.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E665 Practice for Determining Absorbed Dose Versus Depth in Materials Exposed to the X-Ray Output of Flash X-Ray Machines (Withdrawn 2000) Withdrawn. The last approved version of this historical standard is referenced on www.astm.org.
E666 Practice for Calculating Absorbed Dose From Gamma or X Radiation
E668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
E1894 Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources
F526 Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines
Keywords
DIC; digital integrated circuits; dose rate; ionizing radiation; radiation dose rate; threshold for upset; upset; Circuitry; Current measurement--semiconductors; Destructive testing--semiconductors; Dose rate threshold; Dosimetry; Electrical conductors (semiconductors); Electron linear accelerator; Flash X-ray machines (FXR); Irradiance/irradiation--semiconductors; Lasers and laser applications; Linear threshold voltage; Radiation exposure--electronic components/devices; Upset threshold; Voltage
ICS Code
ICS Number Code 31.200 (Integrated circuits. Microelectronics)
DOI: 10.1520/F0744M-97
ASTM International is a member of CrossRef.