FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-F3429/F3429M 2024ASTM F3429/F3429M-24Redline Standard: Standard Specification for Performance of Flame Mitigation Devices Installed in Disposable and Pre-Filled Flammable Liquid ContainersASTM F3429/F3429MScope 1.1 This specification establishes performance requirements for the performance of flame mitigation devices (FMDs) installed in disposable and pre-filled liquid containers, intended for consumer use where the liquid flashpoint is below 60 ºC [140 ºF]. (See Appendix X1.) 1.1.1 Uses of disposable and pre-filled flammable liquid containers include but are not limited to fuels, fire starters, and additives for internal combustion engines. 1.1.2 An FMD that complies with this specification minimizes the potential of flame jetting or container rupture from occurring. 1.1.3 Containers without a significant area reduction at the container opening are not covered because there is no hazard of a flame jet or container rupture because an internal pressure rise does not result from an internal ignition. (See X1.5.) 1.2 This specification does not apply to the following containers: 1.2.1 Containers greater than 20 L [5.3 gal] or smaller than 100 mL [3.4 oz] in volume. 1.2.2 Containers intended for beverages. 1.2.3 Portable fuel containers as defined in Specification F852/F852M. 1.2.4 One-time use portable emergency fuel containers for use by consumers as defined in Specification F2874. 1.2.5 Containers not intended to be open to ambient conditions such as those for liquefied petroleum gas. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Information on specific hazards associated with the test methods in this specification is shown in Section 4.4. 1.5 This specification does not address hazards caused by fire and explosion nor hazards from vapors external to the container when the fuel in the container does not ignite. Further, this specification does not consider scenarios where confinement, obstructions, or preheating cause flame acceleration prior to the flame front reaching the interior of the container. 1.6 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of the materials, products, or assemblies under actual fire conditions. 1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. Keywords disposable flammable liquid container; flame mitigation device; ICS Code ICS Number Code 55.140 (Barrels. Drums. Canisters) DOI: 10.1520/F3429_F3429M-24 This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|