FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-F2147 2010ASTM F2147 - 01(2010)Standard Practice for Guinea Pig: Split Adjuvant and Closed Patch Testing for Contact AllergensActive Standard ASTM F2147 | Developed by Subcommittee: F04.16 Book of Standards Volume: 13.01 ASTM F2147Abstract This practice is intended to determine the potential for a substance, or material extract, to elicit contact dermal allergenicity. It is intended as an alternative to the Guinea Pig Maximization Test (GPMT), given the limitations on dosage form and tendency for false positives associated with the latter test. The split adjuvant method is used when topical application is considered relevant, and the dosage form is a solid, liquid, extract, paste, or gel. The method includes four induction doses applied over a period of time to the same shaved or depilated site on guinea pigs, followed by occlusive patching. Freund's Complete Adjuvant (FCA) is injected near the dose site on a specific time, (second induction dose). Following a rest period, animals are challenged at a previously unexposed site, and the reaction evaluated at regular intervals. The closed patch method is used when topical application is relevant, but the preferred dosage form does not permit injection under the skin or intradermally, and the discomfort involved with extended occlusive patching and adjuvant use is to be avoided. It involves repeated induction doses over a period of time at the same shaved/depilated site, followed each time by occlusive wrapping. After a rest period, animals are challenged at previously untreated sites, and their reactions evaluated after a period of time. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. Significance and Use In selecting a material for human contact in medical applications, it is important to ensure the material will not stimulate the immune system to produce an allergic reaction under relevant exposure conditions. Extractable chemicals produced by skin contact or during physiological exposures may cause allergic reactions. Therefore, this practice provides for evaluations of solid or semisolid dosage forms using material extracts or direct evaluation of the test article. The rationale for this animal model is based on the fact that the guinea pig has been shown to be an appropriate animal model for predicting human contact dermatitis; its tractable nature, its availability from reputable suppliers, the historical database of information already acquired using this species, and the correlation of such results to data on known human allergens, all contribute to its widespread use for allergenicity studies (1-5) . The need for sensitization procedures other than the maximization test (Practice F720 ) is based on: ( 1 ) the need for a route of exposure more similar to use conditions, ( 2 ) concern over the use of adjuvant because of its recruitment of cell types to the test site which are not typically involved in immunologic reactions, and because of the discomfort this causes in the animals, ( 3 ) absence of a proper FCA-irritant control group in the traditional maximization design, and ( 4 ) the frequency of false positives often encountered with the GPMT. Both of these tests are internationally accepted (1) . 1. Scope 1.1 This practice is intended to determine the potential for a substance, or material extract, to elicit contact dermal allergenicity. 1.2 This practice is intended as an alternative to the Guinea Pig Maximization Test (GPMT), given the limitations on dosage form and tendency for false positives associated with the latter test. See Rationale and References. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards F619 Practice for Extraction of Medical Plastics F720 Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test ISO Document ISO10993-10,1995 Tests for Irritation and Sensitization Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.Keywords acute toxicity; allergenicity; biocompatibility; guinea pigs; immunotoxicity; sensitization; Cement mortars; ICS Code ICS Number Code 11.100 (Laboratory medicine) DOI: 10.1520/F2147-01R10 ASTM International is a member of CrossRef. ASTM F2147This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|