1. Scope
1.1 This test method covers the quantitative determination of the rate of moisture vapor emitted from below-grade, on-grade, and above-grade (suspended) bare concrete floors.
1.2 This test shall not be used to evaluate the rate of moisture vapor emitted by lightweight concrete floors containing lightweight aggregate.
1.3 This test shall not be used to evaluate moisture vapor emissions over coatings on concrete or over patching or leveling compounds.
1.4 This quantity of moisture shall be expressed as the rate of moisture vapor emission, measured in pounds of moisture over a 1000 ft 2 area during a 24-h period.
1.5 This test shall not be used to evaluate moisture emissions over gypsum concrete.
1.6 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E1745 Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs
E1993 Specification for Bituminous Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs
F141 Terminology Relating to Resilient Floor Coverings
Resilient Floor Covering Institute Standard
RecommendedWorkPractMilitary Standard
MIL-PRF-131 Barrier Materials, Waterproof, Greaseproof, Flexible, Heat-SealableICRI Guide
ICRITechnicalGuideli Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer OverlaysKeywords
anhydrous calcium chloride; moisture vapor emission rate; quantitative calcium chloride; resilient flooring: Vapor phase analysis/processing; Anhydrous calcium chloride; Calcium chloride; Flooring/floor covering systems (concrete); Moisture analysis--building materials/applications; Moisture analysis--concrete; Resilient flooring; RMA referee test;
ICS Code
ICS Number Code 91.100.30 (Concrete and concrete products); 91.060.30 (Ceilings. Floors. Stairs)