FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-F1580 2012ASTM F1580 - 12Standard Specification for Titanium and Titanium-6 Aluminum-4 Vanadium Alloy Powders for Coatings of Surgical ImplantsActive Standard ASTM F1580 | Developed by Subcommittee: F04.12 Book of Standards Volume: 13.01 ASTM F1580Abstract This specification covers the chemical, particle size, and cleanliness requirements for unalloyed titanium and titanium-6aluminum-4vanadium alloy powders for use as coatings, formed by sintering or thermal spraying techniques, onto titanium alloy surgical implants. The powders may be manufactured by the plasma rotating electrode, inert gas atomization, or hydride-dehydride process, or other method capable of producing powder meeting the requirements of this specification. This specification addresses only the powder requirements, and not the properties of the coatings formed from them. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers the requirements for unalloyed titanium and Ti-6Al-4V alloy powders for use in fabricating coatings on titanium alloy implants. 1.2 Powders covered under this specification may be used to form coatings by sintering or thermal spraying techniques. 1.3 This specification covers powder requirements only. It does not address properties of the coatings formed from them. 1.4 Finely divided titanium powder may be considered pyrophoric and should be handled in accordance with the appropriate guidelines. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
ASTM Standards B214 Test Method for Sieve Analysis of Metal Powders B215 Practices for Sampling Metal Powders B299 Specification for Titanium Sponge E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications E2371 Test Method for Analysis of Titanium and Titanium Alloys by Atomic Emission Plasma Spectrometry F67 Specification for Unalloyed Titanium, for Surgical Implant Applications (UNS R50250, UNS R50400, UNS R50550, UNS R50700) F981 Practice for Assessment of Compatibility of Biomaterials for Surgical Implants with Respect to Effect of Materials on Muscle and Bone F1472 Specification for Wrought Titanium-6Aluminum-4Vanadium Alloy for Surgical Implant Applications (UNS R56400) ISO Standards ISO 9001 Quality Management System RequirementsAerospace Material Specifications AMS 4998 Powder, 6Al-4VKeywords coatings; metallic; metals (for surgical implants titanium alloys); orthopaedic medical devices (titanium/titanium alloys); powder; porous coatings; titanium/titanium alloys (for surgical implants); Metallic coatings; Metallic surgical implant materials--specifications; Metal powders--specifications; Metals (for surgical implants)--titanium alloys; Orthopaedic medical devices--specifications (Ti/Ti alloy); Porous coatings--specifications; Powder coatings; Powders; Titanium (Ti) (for surgical implants)--specifications; Surgical implants--specifications ICS Code ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics); 77.120.50 (Titanium and titanium alloys) DOI: 10.1520/F1580-12 ASTM International is a member of CrossRef. ASTM F1580The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|