FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E492 2009ASTM E492 - 09Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping MachineActive Standard ASTM E492 | Developed by Subcommittee: E33.03 Book of Standards Volume: 04.06 ASTM E492Significance and Use The spectrum of the noise in the room below the test specimen is determined by the following: The size and the mechanical properties of the floor-ceiling assembly, such as its construction, surface, mounting or edge restraints, stiffness, or internal damping, The acoustical response of the room below, The placement of the object or device producing the impacts, and The nature of the actual impact itself. This test method is based on the use of a standardized tapping machine of the type specified in 8.1 placed in specific positions on the floor. This machine produces a continuous series of uniform impacts at a uniform rate on a test floor and generates in the receiving room broadband sound pressure levels that are sufficiently high to make measurements possible beneath most floor types even in the presence of background noise. The tapping machine itself, however, is not designed to simulate any one type of impact, such as produced by male or female footsteps. Because of its portable design, the tapping machine does not simulate the weight of a human walker. Therefore, the structural sounds, i.e., creaks or booms of a floor assembly caused by such footstep excitation is not reflected in the single number impact rating derived from test results obtained by this test method. The degree of correlation between the results of tapping machine tests in the laboratory and the subjective acceptance of floors under typical conditions of domestic impact excitation is uncertain. The correlation will depend on both the type of floor construction and the nature of the impact excitation in the building. In laboratories designed to satisfy the requirements of this test method, the intent is that only significant path for sound transmission between the rooms is through the test specimen. This is not generally the case in buildings where there are often many other paths for sounds flanking sound transmission . Consequently sound ratings obtained using this test method do not relate directly to sound isolation in buildings; they represent an upper limit to what would be measured in a field test. This test method is not intended for field tests. Field tests are performed according to Test Method E 1007. 1. Scope 1.1 This test method covers the laboratory measurement of impact sound transmission of floor-ceiling assemblies using a standardized tapping machine. It is assumed that the test specimen constitutes the primary sound transmission path into a receiving room located directly below and that a good approximation to a diffuse sound field exists in this room. 1.2 Measurements may be conducted on floor-ceiling assemblies of all kinds, including those with floating-floor or suspended ceiling elements, or both, and floor-ceiling assemblies surfaced with any type of floor-surfacing or floor-covering materials. 1.3 This test method prescribes a uniform procedure for reporting laboratory test data, that is, the normalized one-third octave band sound pressure levels transmitted by the floor-ceiling assembly due to the tapping machine. 1.4 Laboratory Accreditation The requirements for accrediting a laboratory for performing this test method are given in Annex A2. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards C423 Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method C634 Terminology Relating to Building and Environmental Acoustics E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements E336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings E989 Classification for Determination of Impact Insulation Class (IIC) E1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures E1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum E2235 Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods ANSI Standards S12.51 Acoustics--Determination of Sound Power Levels of Noise Sources Using Sound Pressure--Precision Methods for Reverberation RoomsISO Standards ISO3741 Determination of Sound Power Levels of Noise Sources Using Sound Pressure--Precision Methods for Reverberation RoomsIEC Standards IEC61672 Electroacoustics--Sound Level Meters--Part 1: SpecificationsKeywords floor ceiling assemblies; impact sound transmission; tapping machine; Acoustical tests; Floor-ceiling assemblies; Impact sound transmission (building elements); Laboratory sound transmission testing; Partitions; Tapping machine method; ICS Code ICS Number Code 91.120.20 (Acoustics in buildings. Sound insulation) DOI: 10.1520/E0492-09 ASTM International is a member of CrossRef. ASTM E492Customers who bought this book also bought...The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |