FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E2361 2013ASTM E2361 - 13Standard Guide for Testing Leave-On Products Using In-Situ MethodsActive Standard ASTM E2361 | Developed by Subcommittee: E35.15 Book of Standards Volume: 11.05 ASTM E2361Significance and Use 4.1 The United States has concentrated attention and testing efforts on surgical scrubbing far more than on hand care in patient-to-patient routines. Great Britain, the originators of infection control nursing, have always had their focus on infection transmission. In the United States, published articles have documented the short exposure time for health care personnel who do wash their hands between patients. The average is less than 10 s. The ideal product for the reduction of transient flora is one that rapidly kills or removes or both the microbial load acquired during health care activities. The emphasis on rapidity is essential simply because health care personnel will not take the necessary time when using conventional hand-washing products. The use of products not intended for use with water has increased dramatically and their use is common in European countries largely because of convenience and effectiveness. A second characteristic is the level of antimicrobial action. The use of a rapid and potent active product to reduce work-acquired microbial flora is ideal. 4.2 Since the change from strictly in-vitro testing of topical antimicrobials for use on skin to simulated use testing in hand washing, prepping, site access testing, and sampling, emphasis has always been on washing hands, agitating, rubbing, and brushing with liquid on the skin site to estimate bacteria removed after testing. 4.3 The use of hard agitation has diminished with surgical scrubs without brushes or with only mild agitation and friction. 4.4 There is a history of microbial dispersal ( 9 ) and increase in surface bacteria from deeper layers resulting from showering ( 10- 12 ) , washing, scrubbing, and agitation. In the normal situation on the skin, there is a superficial, surface flora and a deeper or hidden flora ( 5 ) . The proportion of one to the other has been addressed by Selwyn ( 4 ) and his judgment is that from 20 to 50?% of the flora is deep. The intent in skin sampling has almost always been to scrub, agitate, and use surfactant to remove as many organisms as we can. In doing this, we have completely ignored the two types of flora. 4.5 Further, when the skin is treated with a cleansing agent or an antimicrobial that is subsequently rinsed away, the deep or hidden flora is pushed to the surface as the sebum replenishes the sebum from the sebaceous glands removed in washing. Many early investigators have looked at simpler sampling methods that we now recognize were sampling primarily the superficial transient flora. 1. Scope 1.1 This guide covers test methods and sampling procedure options for leave-on products for consumer and hospital personnel. Leave-on products, such as alcohol hand rubs and lotions containing antimicrobial ingredients, are increasingly marketed and used by consumers and health care personnel. These products are distinguished from conventional washing and scrubbing preparations in that they do not rely on the rinsing, physical removal, and antimicrobial action in determining their effectiveness. Although agitation and friction may serve to release organisms from the skin and folds and crevices, organisms are then killed in situ and are not rinsed from the skin surface before sampling. Appropriate test methods for the hands have been published, while other sampling methods will be needed for testing body areas other than the hands. 1.1.1 Researchers have described techniques to identify the expanded flora we now know can be present on the skin. It is impractical, if not prohibitive to attempt to recover and identify these varieties of organisms with each test. At some point in the design of a test, a decision is necessary for defining the target organisms. Should the sampling be designed to recover as much of the microflora as possible or a particular portion of it? Consideration of transient and resident, superficial and deep, or aerobic and anaerobic flora must be included in defining the objective in testing products. The recovery methods selected for any testing must be based on the projected use of the product type being tested. 1.2 Methods of recovery after application of the contaminating organisms to a part of the body other than by the agitation/rubbing of the hands against a glass petri plate also need examination. Consideration should be given to contact plating, controlled swabbing with a template, and cup scrubbing (detergent/agitation used) since the target organisms for recovery are likely to be on the superficial layers of skin. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
ASTM Standards E1174 Test Method for Evaluation of the Effectiveness of Health Care Personnel Handwash Formulations E1327 Test Method for Evaluation of Antimicrobial Handwash Formulations by Utilizing Fingernail Regions Keywords antimicrobial products; in-situ methods; leave-on products; recovery techniques; ICS Code ICS Number Code 11.140 (Hospital equipment) DOI: 10.1520/E2361 ASTM International is a member of CrossRef. ASTM E2361The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|