FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E1838 2010ASTM E1838 - 10Standard Test Method for Determining the Virus-Eliminating Effectiveness of Hygienic Handwash and Handrub Agents Using the Fingerpads of AdultsActive Standard ASTM E1838 | Developed by Subcommittee: E35.15 Book of Standards Volume: 11.05 ASTM E1838Significance and Use This in vivo procedure is designed to test the ability of hygienic handwash and handrub agents to reduce levels of selected infectious viruses from experimentally contaminated fingerpads of adults. Since the two thumbpads and all eight fingerpads can be used in any given test, it allows for the incorporation of input virus control (two), virus remaining viable after the inoculum has been allowed to dry (two), virus eliminated after treatment with a control or reference solution (two), and up to four replicates to assess the virus-eliminating efficiency of the substance under test. No more than 100 ? L of the virus suspension are required to complete one test. The results of testing with this test method may form the basis for further tests using a suitable whole-hand test protocol (for example, Test Method E2011 ). This test method is designed to be performed by a trained individual, who is responsible for choosing the appropriate host system for the test virus and applying the techniques necessary for propagation and maintenance of host and test virus. For a reference text, refer to Lennette et al (8) . Whereas the method described here relates to testing with viruses of human origin, it can be readily adapted to work with animal pathogenic viruses as well as bacteriophages. Standard methods for working with bacteria (Test Method E2276 ) and fungi (Test Method E2613 ) are also available. Infectious microorganisms left on hands after washing can be reduced further by drying the washed hands with paper, cloth, or warm air (9) . A step for the drying of fingerpads after exposure to the control or test substance, therefore, has not been included to avoid virus removal by the drying process itself. This test method is not meant for use with surgical hand scrubs or preoperative skin preps. The level of viable virus on each fingerpad after the drying of the inoculum should not be less than 10 4 infectious units which would permit the detection of up to a 4 log 10 reduction in the infectivity titer of the virus by the test substance under the conditions of this test method. 1. Scope 1.1 Human skin is not known to carry viruses as a part of its resident microbiota. Hands transiently contaminated with viruses can, however, act as vehicles for the spread of many types of viral infections. Hand hygiene is meant to reduce the load of viruses and other transient microorganisms on hands, thereby reducing the risk of disease transmission. Such reductions in the virus load may be due to a combination of virus inactivation and mechanical removal of infectious virus from the skin. 1.2 This test method is designed to determine the comparative virus-eliminating effectiveness of microbicidal or non-microbicidal formulations. This test method is not meant for use with surgical hand scrubs or preoperative skin preps. Note 1The test method should be performed by persons with training in virology in facilities designed and equipped for work with infectious agents at biosafety level 2 (6). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards E2011 Test Method for Evaluation of Hygienic Handwash and Handrub Formulations for Virus-Eliminating Activity Using the Entire Hand E2276 Test Method for Determining the Bacteria-Eliminating Effectiveness of Hygienic Handwash and Handrub Agents Using the Fingerpads of Adults E2613 Test Method for Determining Fungus-Eliminating Effectiveness of Hygienic Handwash and Handrub Agents Using Fingerpads of Adults Keywords adenovirus; cell culture; cytotoxicity; eluent; fingerpads; hepatitis A virus; hygienic handwashing; hygienic handrub agent; infection control; influenzavirus; in vivo testing; microbicidal soap; rhinovirus; rotavirus; skin microbiota; soil load; standard hard water; virus; virus elution; Cell culture; Cytotoxicity; Fingerpads; Germicidal compounds/applications; Handwashing/handrubbing agents; Hard water; Hygienic handwashing; Infection control; Influenzavirus; Rotavirus; Skin flora; Virology; ICS Code ICS Number Code 11.080.01 (Sterilization and disinfection in general) DOI: 10.1520/E1838-10 ASTM International is a member of CrossRef. ASTM E1838The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|