FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E1510 2013ASTM E1510-95-e1-Reapproved2013Historical Standard: Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas ChromatographsASTM E1510Scope 1.1 This practice covers the installation and maintenance of fused silica capillary columns in gas chromatographs that are already retrofitted for their use. This practice excludes information on: 1.1.1 Injection techniques. 1.1.2 Column selection. 1.1.3 Data acquisition. 1.1.4 System troubleshooting and maintenance. 1.2 For additional information on gas chromatography, please refer to Practice E260. For specific precautions, see 7.2.2.2(1), 7.2.2.2(2), 7.2.7, and 7.2.7.2. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety information, see Section 6, 7.2.2.2(1), 7.2.2.2(2), 7.2.7, and 7.2.7.2.2
TABLE 1 Typical Splitter Vent Flow Rates (50 to 1 split ratio) (at optimum linear velocity)
Note 1—The curves were generated by plotting the height equivalent to a theoretical plate (length of column divided
by the total number of theoretical plates, H.E.T.P.) against the column's average linear velocity. The lowest point on the curve indicates the carrier gas velocity in which the highest column
efficiency is reached.
Note 2—Gases information available from Compressed Gas Association (CGA), 4221 Walney Rd., 5th Floor, Chantilly, VA
20151-2923, http://www.cganet.com.
FIG. 1 Van Deemter Profile for Hydrogen, Helium, and Nitrogen Carrier Gases
Note 1—Fig. 2 shows that the resolution is similar but the analysis time is
reduced by 50 % when comparing hydrogen to helium in an isothermal analysis using optimum flow velocities.
Note 2—Hydrogen provides similar resolution in one-half the analysis time of helium for an isothermal
analysis.
Note 3—
Note 4—30 m, 0.25-mm ID, 0.25 μm 5 % diphenyl − 95 % dimethyl polysiloxane 0.1-μL split injection of chlorinated
pesticides.
FIG. 2 Hydrogen Versus Helium (Isothermal Analysis)
FIG. 3 Capping Silanol Groups with Dimethyl Dichlorosilane (DMDCS)
Note 1—Septum bleed can obscure or co-elute with compounds of interest, thus decreasing the analytical
accuracy.
Note 2—
Note 3—30 m, 0.53-mm ID, 0.50 μm 5 % diphenyl − 95 % dimethyl polysiloxane 0.1 μL direct injection of 50 pg
pesticide standard.
FIG. 4 ECD Septum Bleed
Keywords capillary columns; capillary gas chromatography; gas chromatographs; installing capillary columns ICS Code ICS Number Code 71.040.50 (Physicochemical methods of analysis) DOI: 10.1520/E1510-95R13E01 This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|