ASTM E1413-06
Historical Standard: ASTM E1413-06 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration
SUPERSEDED (see Active link, below)
ASTM E1413
1. Scope
1.1 This practice describes the procedure for separation of small quantities of ignitable liquid residues from fire debris samples using the absorption/elution method of headspace concentration.
1.2 Both positive and negative pressure systems are described.
1.3 While this practice is suitable for successfully extracting ignitable liquid residues over the entire range of concentration, the headspace concentration methods are best used when a high level of sensitivity is required due to a very low concentration of ignitable liquid residues in the sample.
1.4 Alternate separation and concentration procedures are listed in Section 2.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E1386 Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Solvent Extraction
E1388 Practice for Sampling of Headspace Vapors from Fire Debris Samples
E1412 Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration With Activated Charcoal
E1459 Guide for Physical Evidence Labeling and Related Documentation
E1492 Practice for Receiving, Documenting, Storing, and Retrieving Evidence in a Forensic Science Laboratory
E1618 Test Method for Ignitable Liquid Residues in Extracts from Fire Debris Samples by Gas Chromatography-Mass Spectrometry
E2154 Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration with Solid Phase Microextraction (SPME)
E2451 Practice for Preserving Ignitable Liquids and Ignitable Liquid Residue Extracts from Fire Debris Samples
Keywords
activated charcoal; dynamic headspace concentration; elution; fire debris samples; forensic science; ignitable liquid residues; Tenax; thermal desorption;
ICS Code
ICS Number Code 13.220.99 (Other standards related to fire protection)
DOI: 10.1520/E1413-06
ASTM International is a member of CrossRef.