FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-E1022 1994ASTM E1022-94Historical Standard: Standard Guide for Conducting Bioconcentration Tests with Fishes and Saltwater Bivalve MollusksASTM E1022Scope 1.1 This guide describes procedures for obtaining laboratory data concerning bioconcentration of a test material added to dilution water-but not to food-by freshwater and saltwater fishes and saltwater bivalve mollusks using the flow-through technique. These procedures also should be useful for conducting bioconcentration tests with other aquatic species, although modifications might be necessary. 1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, the results of tests conducted using unusual procedures are not likely to be comparable to those of many other tests. The comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting bioconcentration tests. 1.3 These procedures are applicable to all chemicals that can be measured accurately at the necessary concentrations in water and in appropriate tissues. Bioconcentration tests are usually conducted on individual chemicals but can be conducted on mixtures if appropriate measurements can be made. Some techniques described in this guide were developed for tests on non-ionizable organic chemicals (see 11.1.2.1) and might not apply to ionizable or inorganic chemicals. 1.4 Results of bioconcentration tests should usually be reported in terms of apparent steady-state and projected steady-state bioconcentration factors (BCFs) and uptake and depuration rate constants. Results should be reported in terms of whole body for fishes and in terms of total soft tissue for bivalve mollusks. For fishes and scallops consumed by humans, some results should also be reported in terms of the edible portion, especially if ingestion of the test material by humans is a major concern. For tests on organic and organometallic chemicals, the percent lipids of the tissue should be reported. 1.5 This guide is arranged as follows: Section Referenced Documents 2 Descriptions of Terms Specific to This Standard 3 Summary of Practice 4 Significance and Use 5 Hazards 6 Apparatus 7 Facilities 7.1 Construction Materials 7.2 Metering System 7.3 Test Chambers 7.4 Cleaning 7.5 Acceptability 7.6 Dilution Water 8 Requirements 8.1 Source 8.2 Treatment 8.3 Characterization 8.4 Test Material 9 General 9.1 Radiolabeled Material 9.2 Stock Solution 9.3 Test Concentration(s) 9.4 Test Organisms 10 Species 10.1 Size 10.2 Source 10.3 Care and Handling 10.4 Feeding 10.5 Disease Treatment 10.6 Holding 10.7 Acclimation 10.8 Quality 10.9 Procedure 11 Experimental Design 11.1 Dissolved Oxygen 11.2 Temperature 11.3 Loading 11.4 Beginning the Test 11.5 Care of Organisms 11.6 Feeding 11.7 Cleaning 11.8 Biological Data 11.9 Measurements on Test Solutions 11.10 Analytical Methodology 12 Acceptability of Test 13 Calculation of Results 14 Report 151.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 6. Keywords Apparent steady-state bioconcentration; Aquatic environments; Bioaccumulation; Bioconcentration factor (BCF); Bivalve molluscs; Depuration phase; Dilution water; Field testing-environmental; Fishes; Flow-through test chambers; Fresh water; Microbiological water quality; Molluscs; Organic compounds; Saltwater; Sampling-water applications; Steady-state bioconcentration; Uptake phase; conducting bioconcentration tests with fishes/saltwater bivalve; molluscs, practice ICS Code ICS Number Code DOI: 10.1520/E1022-94 The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|