Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94624)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    D7053/D7053M-11 Standard Guide for Determining and Evaluating Causes of Water Leakage of Low-Sloped Roofs
    Edition: 2011
    $103.58
    Unlimited Users per year

Description of ASTM-D7053 2011

ASTM D7053 / D7053M - 11

Standard Guide for Determining and Evaluating Causes of Water Leakage of Low-Sloped Roofs

Active Standard ASTM D7053 / D7053M | Developed by Subcommittee: D08.20

Book of Standards Volume: 04.04




ASTM D7053 / D7053M

Significance and Use

This guide is intended to provide building professionals with a methodology for evaluating water leakage through low-sloped roofs. It addresses the service history of a roof, the various components of a roof, and the interaction between these components and adjacent construction. It is not intended as a construction quality control procedure, as specified in Practice D7186 , nor as a preconstruction qualification procedure. It is intended for evaluating water leakage through a low-sloped roof.

Qualifications Use of this guide requires a background as an architect, engineer, roof/waterproofing consultant, roofing contractor, or related profession with an understanding in building construction and the expertise in the design, installation, and maintenance of low-sloped roofs.

Application The sequential activities described herein are intended to produce an evaluation program, but all activities may not be applicable or necessary for a particular evaluation program. It is the responsibility of the professional using this guide to determine the activities and sequence necessary to perform an appropriate leakage evaluation for a specific low-sloped roof on a building.

Preliminary Assessment A preliminary assessment may indicate that water leakage problems are limited to a specific element or portion of a low-sloped roof. The evaluation of causes may be limited in scope, and the procedures recommended herein abridged according to the professional judgment of the investigator. A statement stipulating the limits of the investigation should be included in the report.

Expectations Expectations about the overall effectiveness of an evaluation program must be reasonable, and in proportion to a defined scope of work. This guide is intended to address leakage of a low-sloped roof system, leading to conclusions that can generally be applied to similar or other locations on the roof. Since every possible location is not included in an evaluation program, it is probable that every leak source will not be identified. Leak sources that are localized and unique may remain, and require specific and localized evaluation effort.

This guide is not intended as a design guide. Reference is made to design features of a low-sloped roof only for the purpose of identifying items of interest for consideration in the evaluation process.

This guide does not address leakage through walls not associated with roof construction, fenestration, or leakage below-grade. It is not intended for use with structures designed to retain water, such as pools, fountains, and vegetative roofs.

1. Scope

1.1 This guide describes methods for determining and evaluating causes of water leakage in low-sloped roofs. For this purpose, water penetration is considered leakage and therefore problematic, is causing or is likely to cause premature deterioration of the roof, building or its contents, or is adversely affecting the performance of other components of the building A roof is considered an assembly including the membrane, insulation, vapor retarder (if required), deck, and structural components.

1.1.1 This guide excludes moisture-related problems in roofs caused by condensation.

Note 1 Condensation Moisture-related problems in roof systems may be caused by condensation of humid air originating from within the building and be incorrectly attributed to leakage from rain water. The protocol for an investigation of dampness due to condensation and is complicated, requires special expertise, and is beyond the scope of this guide. For information regarding condensation problems as they relate to roofs, refer to ASTM MNL 18, ASTM MNL 40, and ASHRAE Handbook 2005 Fundamentals.

1.2 Investigative techniques discussed in this guide may be intrusive, disruptive, or destructive. It is the responsibility of the investigator to establish the limitations of use, to anticipate and advise of the destructive nature of some procedures, and to plan for repairing and selective reconstruction as necessary.

1.3 This guide does not address steep-sloped roofs, standing or flat seam metal roofs, or architectural standing seam metal roofs.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C1153 Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging

D1079 Terminology Relating to Roofing and Waterproofing

D7186 Practice for Quality Assurance Observation of Roof Construction and Repair


Keywords

evaluation; inspection; leaks; low-sloped roof; roof; testing; water leakage; Low-sloped roofs; Roofing membranes; Water leakage;


ICS Code

ICS Number Code 91.060.20 (Roofs)


DOI: 10.1520/D7053_D7053M-11

ASTM International is a member of CrossRef.

ASTM D7053 / D7053M

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $727.42 Buy
VAR
ASTM
[+] $10,801.41 Buy
VAR
ASTM
[+] $5,812.65 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X