ASTM D6522-00
Historical Standard: ASTM D6522-00 Standard Test Method for Determination of Nitrogen Oxides, Carbon Monoxide, and Oxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines, Combustion Turbines, Boilers, and Process Heaters Using Portable Analyzers
SUPERSEDED (see Active link, below)
ASTM D6522
1. Scope
1.1 This test method covers the determination of nitrogen oxides (NO and NO 2 ), carbon monoxide (CO), and oxygen (O 2 ) concentrations in controlled and uncontrolled emissions from natural gas-fired reciprocating engines, combustion turbines, boilers, and process heaters. Due to the inherent cross sensitivities of the electrochemical cells, this test method should not be applied to other pollutants or emission sources without a complete investigation of possible analytical interferences and a comparative evaluation with EPA test methods.
1.1.1 The procedures and specifications of this method were developed during laboratory and field tests funded by the Gas Research Institute (GRI). Comparative emission tests were conducted only on natural gas-fired combustion sources.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
EPA Methods from 40 CFR Part 60, Appendix A
Method20 - Determination of Nitrogen Oxides, Sulfur Dioxide, and Diluent Emissions from Stationary Gas TurbinesEPA Methods from 40 CFR Part 63, Appendix A
Method301 --Field Validation of Pollutant Measurement Methods from Various Waste MediaEPA Methods from 40 CFR Part 75, Appendix H
RevisedTraceabilityP Protocol G1 and G2 Procedures EPA-600/R-97/121, EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, September 1997, as amended August 25, 1999. Available from: http://www.epa.gov/ttn/emc/news.html.Keywords
carbon monoxide emissions; electrochemical cells; emissions; natural gas combustion; oxygen emissions; portable analyzers; test method for nitrogen oxides; Automotive engine fuels/oils; Boilers; Carbon monoxide (CO); Emission monitoring; Natural gas-fired reciprocating engines; Nitrogen oxides; Oxygen service/systems; Portable analyzers; Process heaters; Turbines
ICS Code
ICS Number Code 13.040.50 (Transport exaust emissions)