ASTM D5167-03
Historical Standard: ASTM D5167-03 Standard Practice for Melting of Hot-Applied Joint and Crack Sealant and Filler for Evaluation
SUPERSEDED (see Active link, below)
ASTM D5167
1. Scope
1.1 This practice establishes the procedure for melting or heating, or both, of hot-applied joint and crack sealants and fillers in preparation for the making of test specimens used in the laboratory evaluations of the sealants and fillers. Refer to the specific standard material specification for sampling requirements, test sample quantity, temperatures and times for melting and heating, and the number of specimens required for testing.
1.2 This practice is applicable to the hot-applied joint and crack sealants and fillers used in both portland cement and asphaltic-concrete pavements.
1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are provided for information purposes only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautions see Section 7.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D5535 Terminology Relating to Formed-in-Place Sealants for Joints and Cracks in Pavements
E1 Specification for ASTM Liquid-in-Glass Thermometers
E171 Practice for Conditioning and Testing Flexible Barrier Packaging
E220 Test Method for Calibration of Thermocouples By Comparison Techniques
Keywords
crack sealant/filler;
ICS Code
ICS Number Code 91.100.50 (Binders. Sealing materials)
DOI: 10.1520/D5167-03