ASTM D5093-90(1997)
Historical Standard: ASTM D5093-90(1997) Standard Test Method for Field Measurement of Infiltration Rate Using a Double-Ring Infiltrometer with a Sealed-Inner Ring
SUPERSEDED (see Active link, below)
ASTM D5093
1. Scope
1.1 This test method describes a procedure for measuring the infiltration rate of water through in-place soils using a double-ring infiltrometer with a sealed inner ring.
1.2 This test method is useful for soils with infiltration rates in the range of 1 X 10 -7 m/s to 1 X 10 -10 m/s. When infiltration rates [>=]1 X 10 -7 m/s are to be measured Test Method D3385 shall be used.
1.3 This test method provides a direct measurement of infiltration rate, not hydraulic conductivity. Although the units of infiltration rate and hydraulic conductivity are similar, there is a distinct difference between these two quantities. They cannot be directly related unless the hydraulic boundary conditions, such as hydraulic gradient and the extent of lateral flow of water are known or can be reliably estimated.
1.4 This test method can be used for natural soil deposits, recompacted soil layers, and amended soils such as soil bentonite and soil lime mixtures.
1.5 The values stated in SI units are to be regarded as standard. The values in parentheses are for information only.
1.6 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D3385 Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer
D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction
D6026 Practice for Using Significant Digits in Geotechnical Data
Keywords
double ring infiltration; in-place infiltration; soil moisture infiltrometer; Clay liners; Double-ring infiltrometers; Field testing--soil; Fine-grained soil; Flow and flow rate--water; Infiltration rate; Soil; Soil-moisture analysis;
ICS Code
ICS Number Code 65.060.35 (Irrigation and drainage equipment)
DOI: 10.1520/D5093-90R97
ASTM International is a member of CrossRef.