FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-D1499 2013ASTM D1499 - 13Standard Practice for Filtered Open-Flame Carbon-Arc Exposures of PlasticsActive Standard ASTM D1499 | Developed by Subcommittee: D20.50 Book of Standards Volume: 08.01 ASTM D1499Significance and Use 4.1 The ability of a plastic material to resist deterioration of its electrical, mechanical, and optical properties caused by exposure to light, heat, and water can be very significant for many applications. This practice is intended to induce property changes associated with end-use conditions, including the effects of sunlight, moisture, and heat. The exposure used in this practice is not intended to simulate the deterioration caused by localized weather phenomena, such as, atmospheric pollution, biological attack, and saltwater exposure. 4.2 Cautions Variation in results may be expected when operating conditions are varied within the accepted limits of this practice. Therefore, no reference to the use of this practice shall be made unless accompanied by a report prepared in accordance with Section 9 that describes the specific operating conditions used. Refer to Practice G151 for detailed information on the caveats applicable to use of results obtained in accordance with this practice.
Note 2 Additional information on sources of variability and on strategies for addressing variability in the
design, execution, and data analysis of laboratory-accelerated exposure tests is found in Guide G141 .
4.2.1 The spectral power distribution of light from an open-flame carbon-arc is significantly different from that produced in light and water exposure devices using other carbon-arc configurations or other light sources. The type and rate of degradation and the performance rankings produced by exposures to filtered open-flame carbon-arcs can be much different from those produced by exposures to other types of laboratory light sources. 4.2.2 Interlaboratory comparisons are valid only when all laboratories use the same type of carbon-arc, filters, and exposure conditions. 4.3 Reproducibility of test results between laboratories has been shown to be good when the stability of materials is evaluated in terms of performance ranking compared to other materials or to a control. 5 , 6 Therefore, exposure of a similar material of known performance (a control) at the same time as the test materials is strongly recommended. It is recommended that at least three replicates of each material be exposed to allow for statistical evaluation of results. 4.4 Test results will depend upon the care that is taken to operate the equipment in accordance with Practice G152 . Significant factors include regulation of line voltage, freedom from salt or other deposits from water, temperature and humidity control, and conditions of the electrodes. 1. Scope 1.1 This practice covers specific procedures and test conditions that are applicable for exposure of plastics in filtered open-flame carbon-arc devices conducted in accordance with Practices G151 and G152 . This practice also covers the preparation of test specimens, the test condition suited for plastics, and the evaluation of test results. 1.2 This practice does not cover enclosed carbon-arc exposures of plastics, which had been allowed in Practice D1499. Enclosed carbon-arc exposures of plastics are described in Practice D6360 , and in G153 , which gives requirements for exposing nonmetallic materials in enclosed carbon-arc devices. 1.3 The values stated in SI units are to be regarded as standard. The values in parentheses are given for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1 This practice is technically equivalent to ISO?4892-4 .
ASTM Standards D3980 Practice for Interlaboratory Testing of Paint and Related Materials D5870 Practice for Calculating Property Retention Index of Plastics D6360 Practice for Enclosed Carbon-Arc Exposures of Plastics E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method G113 Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials G141 Guide for Addressing Variability in Exposure Testing of Nonmetallic Materials G147 Practice for Conditioning and Handling of Nonmetallic Materials for Natural and Artificial Weathering Tests G151 Practice for Exposing Nonmetallic Materials in Accelerated Test Devices that Use Laboratory Light Sources G152 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials G153 Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials G169 Guide for Application of Basic Statistical Methods to Weathering Tests ISO Standard ISO 4892-4 Plastics--Methods of Exposure to Laboratory Light Sources--Part 4, Open-Flame Carbon Arc LampKeywords carbon-arc; degradation; exposure; light exposure; open-flame carbon-arc; ultraviolet; ICS Code ICS Number Code 83.080.01 (Plastics in general) DOI: 10.1520/D1499 ASTM International is a member of CrossRef. ASTM D1499The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|