FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-C270 2012ASTM C270 - 12aStandard Specification for Mortar for Unit MasonryActive Standard ASTM C270 | Developed by Subcommittee: C12.03 Book of Standards Volume: 04.05 ASTM C270Abstract This specification covers mortars for use in the construction of non-reinforced and reinforced unit masonry structures. Four types of mortar are covered in each of two alternative specifications: (1) proportion specifications and (2) property specifications. The property specification applies to mortar mixed to a specific flow in the laboratory. When neither proportion nor property specifications are specified, the proportion specifications shall govern, unless data are presented to and accepted by the specifier to show that mortar meets the requirements of the property specifications. This specification does not cover the determination of mortar strengths through field testing. The compressive strength values resulting from field tested mortars do not represent the compressive strength of mortar tested in the laboratory nor that of the mortar in the wall. Physical properties of field sampled mortar shall not be used to determine compliance to this specification and are not intended as criteria to determine the acceptance of rejection of the mortar. Compliance to this specification is verified by confirming that the materials used are as specified, meet the requirements as given, and added to the mixer in the proper proportions as described. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers mortars for use in the construction of non-reinforced and reinforced unit masonry structures. Four types of mortar are covered in each of two alternative specifications: ( 1 ) proportion specifications and ( 2 ) property specifications.
Note 1 When the property specification is used to qualify masonry mortars, the testing agency performing the
test methods should be evaluated in accordance with Practice C1093 .
1.2 The proportion or property specifications shall govern as specified. 1.3 When neither proportion or property specifications are specified, the proportion specifications shall govern, unless data are presented to and accepted by the specifier to show that mortar meets the requirements of the property specifications. 1.4 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.5 The terms used in this specification are identified in Terminologies C1180 and C1232 . 1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 The following safety hazards caveat pertains only to the test methods section of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards C5 Specification for Quicklime for Structural Purposes C91 Specification for Masonry Cement C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) C110 Test Methods for Physical Testing of Quicklime, Hydrated Lime, and Limestone C128 Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine Aggregate C144 Specification for Aggregate for Masonry Mortar C150 Specification for Portland Cement C188 Test Method for Density of Hydraulic Cement C207 Specification for Hydrated Lime for Masonry Purposes C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency C511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes C595 Specification for Blended Hydraulic Cements C780 Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit Masonry C952 Test Method for Bond Strength of Mortar to Masonry Units C979 Specification for Pigments for Integrally Colored Concrete C1072 Test Methods for Measurement of Masonry Flexural Bond Strength C1093 Practice for Accreditation of Testing Agencies for Masonry C1157 Performance Specification for Hydraulic Cement C1180 Terminology of Mortar and Grout for Unit Masonry C1232 Terminology of Masonry C1324 Test Method for Examination and Analysis of Hardened Masonry Mortar C1329 Specification for Mortar Cement C1384 Specification for Admixtures for Masonry Mortars C1489 Specification for Lime Putty for Structural Purposes C1506 Test Method for Water Retention of Hydraulic Cement-Based Mortars and Plasters C1586 Guide for Quality Assurance of Mortars E72 Test Methods of Conducting Strength Tests of Panels for Building Construction E514 Test Method for Water Penetration and Leakage Through Masonry E518 Test Methods for Flexural Bond Strength of Masonry Masonry Industry Council HotandColdWeatherMas January 1999Keywords air content; compressive strength; masonry; masonry cement; mortar; portland cement-lime; water retention; water retentivity; ICS Code ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar) DOI: 10.1520/C0270-12A ASTM International is a member of CrossRef. ASTM C270This book also exists in the following packages...
Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|