Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(337)
(589)
(54)
(234)
(996)
(657)
(2161)
(117)
(94394)
(54)
(568)
(124)
(33)
(21)
(20)
(94534)
(3)
(17)
(1)
(374)
(315)
(6731)
(241)
(16)
(6)
(1646)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    C1303/C1303M-19 Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
    Edition: 2019
    $148.51
    Unlimited Users per year

Description of ASTM-C1303/C1303M 2019

ASTM C1303/C1303M-19

Historical Standard: Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation




ASTM C1303/C1303M

Scope

1.1 This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions (1-5) .2

Note 1: See Terminology, 3.2.1, for the meaning of the word aging within this standard.

1.2 Rigid gas-filled closed-cell foam insulation includes all cellular plastic insulations manufactured with the intent to retain a blowing agent other than air.

1.3 This test method is limited to unfaced or permeably faced, homogeneous materials. This method is applied to a wide range of rigid closed-cell foam insulation types, including but not limited to: extruded polystyrene, polyurethane, polyisocyanurate, and phenolic. This test method does not apply to impermeably faced rigid closed-cell foams or to rigid closed-cell bun stock foams.

Note 2: See Note 8 for more details regarding the applicability of this test method to rigid closed-cell bun stock foams.

1.4 This test method utilizes referenced standard test procedures for measuring thermal resistance. Periodic measurements are performed on specimens to observe the effects of aging. Specimens of reduced thickness (that is, thin slices) are used to shorten the time required for these observations. The results of these measurements are used to predict the long-term thermal resistance of the material.

1.5 The test method is given in two parts. The Prescriptive Method in Part A provides long-term thermal resistance values on a consistent basis that can be used for a variety of purposes, including product evaluation, specifications, or product comparisons. The Research Method in part B provides a general relationship between thermal conductivity, age, and product thickness.

1.5.1 To use the Prescriptive Method, the date of manufacture must be known, which usually involves the cooperation of the manufacturer.

1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 Table of Contents: 

 

Section

Scope

1

Reference Documents

2

Terminology

3

Summary of Test Method

4

Significance and Use

5

Part A: The Prescriptive Method

6

  Applicability

6.1

    Qualification Requirements

6.1.1

    Facing Permeability

6.1.2

  Apparatus

6.2

  Sampling

6.3

    Schedule

6.3.1

  Specimen Preparation

6.4

    Goal

6.4.1

    Schedule

6.4.2

    Replicate Test Specimen Sets

6.4.3

    Specimen Extraction

6.4.4

    Slice Flatness

6.4.5

    Slice Thickness

6.4.6

    Stack Composition

6.4.7

  Storage Conditioning

6.5

  Test Procedure

6.6

    Thermal Resistance Measurement Schedule

6.6.1

    Thermal Resistance Measurements

6.6.2

    Product Density

6.6.3

  Calculations

6.7

Part B: The Research Method

7

  Background

7.1

  TDSL Apparatus

7.2

  Sampling Schedule

7.3

  Specimen Preparation

7.4

  Storage Conditioning

7.5

  Test Procedure

7.6

  Calculations

7.7

Reporting

8

 Reporting for Part A, the Prescriptive Method

8.1

 Reporting for Part B, the Research Method

8.2

Precision and Bias

9

Keywords

10

Mandatory Information – Qualification

Annex A1

 Specimen Preparation

A1.1

 Homogeneity Qualification

A1.2

Thermal Conductivity Equivalence Test Procedure

A1.3

 Alternate Product Thickness Qualification

A1.4

Example Calculations

A1.5

Mandatory Information-Preparation of Test Specimens for Spray-Foam Products

Annex A2

Effect Of TDSL

Appendix X1

History of the Standard

Appendix X2

Theory of Foam Aging

Appendix X3

References

 

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Keywords

aging; long-term thermal resistance; LTTR; rigid closed-cell plastic foams; scaling factors; thermal insulation; thermal resistance; time-averaged thermal resistance;


ICS Code

ICS Number Code 83.100 (Cellular materials)


DOI: 10.1520/C1303_C1303M-19

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,369.19 Buy
VAR
ASTM
[+] $10,801.41 Buy
VAR
ASTM
[+] $5,812.65 Buy
VAR
ASTM
[+] $3,560.85 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X