1. Scope
1.1 This practice establishes an experimental procedure for determining the sensitivity of heat flux transducers (HFTs) that are relatively thin. The term sensitivity in this practice refers to the ratio of HFT electrical output to heat flux through the HFT.
1.1.1 For the purpose of this standard, the thickness of the HFT shall be less than 15 % of the narrowest planar dimension of the HFT.
1.2 This practice discusses two methods for determining HFT sensitivity. The first method is the calibration of the HFT in unperturbed heat flow normal to the surface of the HFT, while the second method is the sensitivity of the HFT in actual use, or the HFT conversion factor.
1.3 This practice should be used in conjunction with Practice C1041 when measuring in-situ heat flux and temperature on industrial insulation systems, and with Practice C1046 when performing in-situ measurements of heat flux on opaque building components.
1.4 This practice is not intended to determine the sensitivity of HFTs that are components of heat flow meter apparatus, as in Test Method C518. Refer to Practice C1132 for this purpose.
1.5 The following safety caveat pertains only to the Specimen Preparation and Procedure portions, Sections and , of this practice: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C1041 Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers
C1044 Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
C1046 Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
C1155 Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
Keywords
calibration; heat flux transducer; in situ testing; sensitivity;
ICS Code
ICS Number Code 17.200.10 (Heat. Calorimetry)
DOI: 10.1520/C1130-90R01