FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-C1130 2012ASTM C1130 - 07(2012)Standard Practice for Calibrating Thin Heat Flux TransducersActive Standard ASTM C1130 | Developed by Subcommittee: C16.30 Book of Standards Volume: 04.06 ASTM C1130Significance and Use 4.1 The use of heat flux transducers on building envelope components provides the user with a means for performing in-situ heat flux measurements. Accurate translation of the heat flux transducer output requires a complete understanding of the factors affecting its output, and a standardized method for determining the heat flux transducer sensitivity for the application of interest. 4.2 The sensitivity of the heat flux transducer is determined primarily by the sensor construction and temperature of operation and the details of the application, including geometry, material characteristics, and environmental factors.
Note 1 Practice C1046 includes an excellent description of heat flux transducer construction.
4.3 The presence of a heat flux transducer is likely to alter the heat flux that is being measured. To determine the heat flow that would occur in the absence of the transducer, it is necessary to either: 4.3.1 Ensure that the installation is adequately guarded ( 1 ) . 3 4.3.2 Adjust the results based on a detailed model or numerical analysis. Such analysis is beyond the scope of this practice, but details can be found in ( 2- 6 ) . 4.3.3 Use the empirically measured heat flux transducer sensitivity measured under conditions that adequately simulate the conditions of use in the final application. 4.4 There are several methods for determining the sensitivity of heat flux transducers, including Test Methods C177 , C518 , C1114 , and C1363 . The selection of the appropriate procedure will depend on the required accuracy and the physical limitations of available equipment. 4.5 This practice describes techniques to establish uniform heat flow normal to the heat flux transducer for the determination of the heat flux transducer sensitivity. 4.6 The method of heat flux transducer application must be adequately simulated or duplicated when experimentally determining the heat flux transducer sensitivity. The two most widely used application techniques are to surface-mount the heat flux transducer or to embed the heat flux transducer in the insulation system.
Note 2 The difference between the sensitivity under uniform normal heat flow versus that for the surface-mounted
or embedded configurations has been demonstrated using multiple mathematical techniques ( 7- 9 ) .
1. Scope 1.1 This practice, in conjunction with Test Method C177 , C518 , C1114 , or C1363 , establishes an experimental procedure for determining the sensitivity of heat flux transducers that are relatively thin. 1.1.1 For the purpose of this standard, the thickness of the heat flux transducer shall be less than 30?% of the narrowest planar dimension of the heat flux transducer. 1.2 This practice discusses a method for determining the sensitivity of a heat flux transducer to one-dimensional heat flow normal to the surface and for determining the sensitivity of a heat flux transducer for an installed application. 1.3 This practice should be used in conjunction with Practice C1046 when performing in-situ measurements of heat flux on opaque building components. 1.4 This practice is not intended to determine the sensitivity of heat flux transducers that are components of heat flow meter apparatus, as in Test Method C518 . 1.5 This practice is not intended to determine the sensitivity of heat flux transducers used for in-situ industrial applications that are covered in Practice C1041 . 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards C168 Terminology Relating to Thermal Insulation C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus C1041 Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers C1044 Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode C1046 Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus C1155 Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus Keywords calibration; heat flux transducer; in situ testing; sensitivity; ICS Code ICS Number Code 17.200.10 (Heat. Calorimetry) DOI: 10.1520/C1130-07R12 ASTM International is a member of CrossRef. ASTM C1130This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |