ASTM C1130-07
Historical Standard: ASTM C1130-07 Standard Practice for Calibrating Thin Heat Flux Transducers
SUPERSEDED (see Active link, below)
ASTM C1130
1. Scope
1.1 This practice, in conjunction with Test Method C 177, C 518, C 1114, or C 1363, establishes an experimental procedure for determining the sensitivity of heat flux transducers that are relatively thin.
1.1.1 For the purpose of this standard, the thickness of the heat flux transducer shall be less than 30 % of the narrowest planar dimension of the heat flux transducer.
1.2 This practice discusses a method for determining the sensitivity of a heat flux transducer to one-dimensional heat flow normal to the surface and for determining the sensitivity of a heat flux transducer for an installed application.
1.3 This practice should be used in conjunction with Practice C 1046 when performing in-situ measurements of heat flux on opaque building components.
1.4 This practice is not intended to determine the sensitivity of heat flux transducers that are components of heat flow meter apparatus, as in Test Method C 518.
1.5 This practice is not intended to determine the sensitivity of heat flux transducers used for in-situ industrial applications that are covered in Practice C 1041.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C1041 Practice for In-Situ Measurements of Heat Flux in Industrial Thermal Insulation Using Heat Flux Transducers
C1044 Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode
C1046 Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components
C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
C1155 Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data
C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
Keywords
calibration; heat flux transducer; in situ testing; sensitivity;
ICS Code
ICS Number Code 17.200.10 (Heat. Calorimetry)
DOI: 10.1520/C1130-07
ASTM International is a member of CrossRef.