Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(338)
(589)
(599)
(55)
(234)
(996)
(690)
(2161)
(117)
(94958)
(58)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(319)
(6732)
(241)
(16)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASHRAE
    ASHRAE Standard 90.1-2016 (I-P Edition) -- Energy Standard for Buildings Except Low-Rise Residential Buildings (ANSI Approved; IES Co-sponsored)
    Edition: 2016
    $188.78
    / user per year

Content Description

Standard 90.1 has been a benchmark for commercial building energy codes in the United States and a key basis for codes and standards around the world for more than 35 years. This standard provides the minimum requirements for energy-efficient design of most buildings, except low-rise residential buildings. It offers, in detail, the minimum energy efficiency requirements for design and construction of new buildings and their systems, new portions of buildings and their systems, and new systems and equipment in existing buildings, as well as criteria for determining compliance with these requirements. It is an indispensable reference for engineers and other professionals involved in design of buildings and building systems. This 2016 edition comprises numerous energy-saving measures and incorporates changes from more than 125 addenda. It also includes the following: Format changes to improve usability and readability: One-column format for easier reading Exceptions separated, indented, and set apart with a smaller font size Italicized defined terms Changes to table formats to provide contrast between rows Structural changes: A new Reference Standard Reproduction Annex 1 is provided at the end of the document. Section 5.1.4 now cites ASHRAE Standard 169 as the source for climatic data, and Annex 1 contains extracts of tables and figures from that standard for the reader’s convenience. Two new climate zones (0A/B) have been added to all prescriptive requirements tables. Significant technical content changes: Building Envelope Envelope verification in support of reduced air infiltration and increased requirements for air leakage of overhead coiling doors. Increased stringency requirements for metal building roofs and walls, fenestration, and opaque doors. Improved clarity on defining exterior walls, building orientation, fault assumptions for the effective R-value of air spaces, and calculation procedures for insulating metal building walls. Lighting Modified requirements for exterior and interior lighting power densities to reflect new lighting levels in the IES Lighting Handbook. Modified requirements for lighting control to add additional controls in some space types and options to others to allow easier application of advanced controls. Mechanical Large, electrically driven chilled-water plants are now required to be monitored for electric energy use and efficiency. Dedicated outdoor air systems now include both efficiency and rating requirements for compliance. Requirements are introduced for designs to include both use category and efficiency class. Requirement that air-cooled DX cooling units with economizers have a monitoring system to determine that the air economizer is working properly. Energy Cost Budget (ECB) and Modeling Appendix G now can be used as a path for compliance with the standard. Changes to elevator, motor, and refrigeration baselines; changes to the baseline for existing building projects; and changes to specific opaque assemblies for the baseline envelope model. Modeling rule changes were made to heat pump auxiliary heat, economizer shutoff, lighting controls, humidification systems, cooling towers, and the simulation of preheat coils.
X
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50
51 52 53 54 55 56 57 58 59 60
61 62 63 64 65 66 67 68 69 70
71 72 73 74 75 76 77 78 79 80
81 82 83 84 85 86 87 88 89 90
91 92 93 94 95 96 97 98 99 100