Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
Washington State Energy Code, 2012
- 2012 WASHINGTON STATE ENERGY CODE BASED ON THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE®
- COPYRIGHT
- PREFACE
- WASHINGTON STATE PREFACE
- EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
- LEGISLATION
- TABLE OF CONTENTS
- IECC—COMMERCIAL PROVISIONS [Go to Page]
- TABLE OF CONTENTS
- CHAPTER 1 [CE] SCOPE AND ADMINISTRATION [Go to Page]
- SECTION C101 SCOPE AND GENERAL REQUIREMENTS [Go to Page]
- TABLE C101.4.3.2 ECONOMIZER COMPLIANCE OPTIONS FOR MECHANICAL ALTERATIONS [Go to Page]
- TABLE C101.4.3.2—continued ECONOMIZER COMPLIANCE OPTIONS FOR MECHANICAL ALTERATIONS
- SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
- SECTION C103 CONSTRUCTION DOCUMENTS
- SECTION C104 INSPECTIONS
- SECTION C105 VALIDITY
- SECTION C106 REFERENCED STANDARDS
- SECTION C107 FEES
- SECTION C108 STOP WORK ORDER
- SECTION C109 BOARD OF APPEALS
- SECTION C110 VIOLATIONS
- SECTION C111 LIABILITY
- CHAPTER 2 [CE] DEFINITIONS [Go to Page]
- SECTION C201 GENERAL
- SECTION C202 GENERAL DEFINITIONS [Go to Page]
- FIGURE C202.1 DAYLIGHT ZONE
- CHAPTER 3 [CE] GENERAL REQUIREMENTS [Go to Page]
- SECTION C301 CLIMATE ZONES [Go to Page]
- TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE AND COUNTY
- SECTION C302 DESIGN CONDITIONS
- SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
- TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS
- TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
- TABLE C303.1.3(4) DEFAULT U-FACTORS FOR SKYLIGHTSa, b, c, d
- TABLE C303.1.3(5) SMALL BUSINESS COMPLIANCE TABLE DEFAULT U-FACTORS FOR VERTICAL FENESTRATION
- CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY [Go to Page]
- SECTION C401 GENERAL
- SECTION C402 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- TABLE C402.1.2 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTSa
- EQUATION C402-1 TARGET UAt [Go to Page]
- EQUATION C402-1—continued TARGET UAT
- EQUATION C402-2 PROPOSED UAP
- EQUATION C402-3 TARGET SHGCAt
- EQUATION C402-4 PROPOSED SHGCAP
- TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa, f [Go to Page]
- TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa, f—continued
- TABLE C402.2.1.1 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
- TABLE C402.3 BUILDING ENVELOPE REQUIREMENTS—FENESTRATION
- EQUATION C4-1
- EQUATION C4-2
- TABLE C402.3.3.1 SHGC ADJUSTMENT MULTIPLIERS
- TABLE C402.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
- SECTION C403 MECHANICAL SYSTEMS [Go to Page]
- EQUATION C4-3
- EQUATION C4-4
- TABLE C403.2.3(1)A MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS [Go to Page]
- TABLE C403.2.3(1)A—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
- TABLE C403.2.3(1)B MINIMUM EFFICIENCY REQUIREMENTS: AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
- TABLE C403.2.3(1)C MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR CONDITIONERS
- TABLE C403.2.3(1)D MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS [Go to Page]
- TABLE C403.2.3(1)D—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS
- TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS [Go to Page]
- TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
- TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS [Go to Page]
- TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
- TABLE 403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
- TABLE C403.2.3(6) RESERVED
- TABLE C403.2.3(7) MINIMUM EFFICIENCY REQUIREMENTS: WATER CHILLING PACKAGESa
- TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
- TABLE C403.2.3(9) HEAT TRANSFER EQUIPMENT
- TABLE C403.2.6 ENERGY RECOVERY REQUIREMENT
- EQUATION C4-5
- TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a, c
- TABLE C403.2.10.1(1) FAN POWER LIMITATION
- TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
- TABLE C403.3.1(1) RESERVED
- TABLE C403.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
- TABLE C403.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
- TABLE C403.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
- EXCEPTION 5 TABLE
- TABLE C403.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
- SECTION C404 SERVICE WATER HEATING (MANDATORY) [Go to Page]
- TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
- SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS [Go to Page]
- TABLE C405.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
- TABLE C405.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD [Go to Page]
- TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD [Go to Page]
- TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
- TABLE C405.6.2(1) EXTERIOR LIGHTING ZONES
- TABLE C405.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
- SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
- SECTION C407 TOTAL BUILDING PERFORMANCE [Go to Page]
- TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
- TABLE C407.5.1(2) HVAC SYSTEMS MAP
- TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
- TABLE C407.5.1(4) NUMBER OF CHILLERS
- TABLE C407.5.1(5) WATER CHILLER TYPES
- SECTION C408 SYSTEM COMMISSIONING [Go to Page]
- FIGURE C408.1.2.1 COMMISSIONING COMPLIANCE CHECKLIST
- SECTION C409 ENERGY METERING AND ENERGY CONSUMPTION MANAGEMENT
- CHAPTER 5 [CE] REFERENCED STANDARDS [Go to Page]
- AAMA
- AHAM
- AHRI
- AMCA
- ANSI
- ASHRAE
- ASME
- ASTM
- CSA
- CTI
- DASMA
- DOE
- IAPMO
- ICC
- IESNA
- ISO
- NEMA
- NFRC
- SMACNA
- UL
- US-FTC
- WDMA
- INDEX [CE]
- IECC—RESIDENTIAL PROVISIONS [Go to Page]
- TABLE OF CONTENTS
- CHAPTER 1 [RE] SCOPE AND ADMINISTRATION [Go to Page]
- PART 1—SCOPE AND APPLICATION [Go to Page]
- SECTION R101 SCOPE AND GENERAL REQUIREMENTS
- SECTION R102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
- PART 2—ADMINISTRATION AND ENFORCEMENT [Go to Page]
- SECTION R103 CONSTRUCTION DOCUMENTS
- SECTION R104 INSPECTIONS
- SECTION R105 VALIDITY
- SECTION R106 REFERENCED STANDARDS
- SECTION R107 FEES
- SECTION R108 STOP WORK ORDER
- SECTION R109 BOARD OF APPEALS
- SECTION R110 VIOLATIONS
- SECTION R111 LIABILITY
- CHAPTER 2 [RE] DEFINITIONS [Go to Page]
- SECTION R201 GENERAL
- SECTION R202 GENERAL DEFINITIONS
- CHAPTER 3 [RE] GENERAL REQUIREMENTS [Go to Page]
- SECTION R301 CLIMATE ZONES [Go to Page]
- TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM HUMID DESIGNATIONS BY STATE AND COUNTY
- SECTION R302 DESIGN CONDITIONS
- SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
- TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
- TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
- TABLE R303.1.3(4) DEFAULT U-FACTORS FOR SKYLIGHTSa, b, c, d
- TABLE R303.1.3(5) SMALL BUSINESS COMPLIANCE TABLE DEFAULT U-FACTORS FOR VERTICAL FENESTRATION
- CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY [Go to Page]
- SECTION R401 GENERAL
- SECTION R402 BUILDING THERMAL ENVELOPE [Go to Page]
- TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
- TABLE R402.1.3 EQUIVALENT U-FACTORSa
- TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION [Go to Page]
- TABLE R402.4.1.1—continued AIR BARRIER AND INSULATION INSTALLATION
- SECTION R403 SYSTEMS [Go to Page]
- TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
- SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
- SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) [Go to Page]
- TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [Go to Page]
- TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
- TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
- SECTION R406 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS [Go to Page]
- TABLE R406.2 ENERGY CREDITS (DEBITS) [Go to Page]
- TABLE R406.2—continued ENERGY CREDITS (DEBITS) [Go to Page]
- TABLE R406.2—continued ENERGY CREDITS (DEBITS)
- CHAPTER 5 [RE] REFERENCED STANDARDS [Go to Page]
- AAMA
- ACCA
- ASHRAE
- ASME
- ASTM
- CSA
- ICC
- NEEA
- NFRC
- US-FTC
- WDMA
- WSU
- INDEX [RE]
- CHAPTER 51-11C WAC WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS [Go to Page]
- TABLE OF CONTENTS
- APPENDIX A DEFAULT HEAT LOSS COEFFICIENTS [Go to Page]
- SECTION A101 GENERAL REQUIREMENTS [Go to Page]
- A101.1 SCOPE
- A101.2 DESCRIPTION
- A101.3 AIR FILMS
- A101.4 COMPRESSION OF INSULATION [Go to Page]
- TABLE A101.4 R-VALUE OF FIBERGLASS BATTS COMPRESSED WITHIN VARIOUS DEPTH CAVITIES
- A101.5 BUILDING MATERIALS [Go to Page]
- TABLE A101.5 DEFAULT R-VALUES FOR BUILDING MATERIALS
- SECTION A102 CEILINGS [Go to Page]
- A102.1 GENERAL [Go to Page]
- TABLE A102.1 DEFAULT U-FACTORS FOR CEILINGS
- A102.1.1 METAL-FRAMED CEILINGS
- A102.2 COMPONENT DESCRIPTION [Go to Page]
- A102.2.1 CEILINGS BELOW A VENTED ATTIC
- A102.2.2 VAULTED CEILINGS
- A102.2.3 ROOF DECKS
- A102.2.4 METAL TRUSS FRAMING [Go to Page]
- TABLE A102.2.4(1) STEEL TRUSSa FRAMED CEILING UO
- TABLE A102.2.4(2) STEEL TRUSSa FRAMED CEILING UO WITH R-3 SHEATHINGb
- TABLE A102.2.4(3) STEEL TRUSSa FRAMED CEILING UO WITH R-5 SHEATHINGb
- TABLE A102.2.4(4) STEEL TRUSSa FRAMED CEILING UO WITH R-10 SHEATHINGb
- TABLE A102.2.4(5) STEEL TRUSSa FRAMED CEILING UO WITH R-15 SHEATHINGb
- A102.2.5 METAL BUILDING ROOF [Go to Page]
- TABLE A102.2.5 DEFAULT U-FACTORS FOR METAL BUILDING ROOFS
- A102.2.5.1 SINGLE LAYER
- A102.2.5.2 DOUBLE LAYER
- A102.2.5.3 CONTINUOUS INSULATION
- A102.2.5.4 LINER SYSTEM (Ls)
- A102.2.5.5 FILLED CAVITY
- A102.2.6 ROOFS WITH INSULATION ENTIRELY ABOVE DECK (UNINTERRUPTED BY FRAMING) [Go to Page]
- TABLE A102.2.6 ASSEMBLY U-FACTORS FOR ROOFS WITH INSULATION ENTIRELY ABOVE DECK (UNINTERRUPTED BY FRAMING)
- SECTION A103 ABOVE-GRADE WALLS [Go to Page]
- A103.1 GENERAL
- A103.2 FRAMING DESCRIPTION [Go to Page]
- A103.2.1 STANDARD
- A103.2.2 INTERMEDIATE
- A103.2.3 ADVANCED
- A103.3 COMPONENT DESCRIPTION [Go to Page]
- A103.3.1 SINGLE-STUD WALL [Go to Page]
- TABLE A103.3.1(1) 2 x 4 SINGLE WOOD STUD: R-11 BATT
- TABLE A103.3.1(2) 2 x 4 SINGLE WOOD STUD: R-13 BATT
- TABLE A103.3.1(3) 2 x 4 SINGLE WOOD STUD: R-15 BATT
- TABLE A103.3.1(4) 2 x 6 SINGLE WOOD STUD: R-19 BATT
- TABLE A103.3.1(5) 2 x 6 SINGLE WOOD STUD: R-21 BATT
- TABLE A103.3.1(6) 2 x 6 SINGLE WOOD STUD: R-22 BATT
- TABLE A103.3.1(7) 2 x 6 SINGLE WOOD STUD: TWO R-11 BATTS
- TABLE A103.3.1(8) 2 x 8 SINGLE STUD: R-25 BATT
- A103.3.2 STRAP WALL [Go to Page]
- TABLE A103.3.2 2 x 6: STRAP WALL
- A103.3.3 DOUBLE STUD WALL [Go to Page]
- TABLE A103.3.3(1) 2 x 6 + 2 x 4: DOUBLE WOOD STUD
- TABLE A103.3.3(2) 2 x 4 + 2 x 4: DOUBLE WOOD STUD
- A103.3.4 LOG WALL [Go to Page]
- TABLE A103.3.4 LOG WALLS
- A103.3.5 STRESS-SKIN PANEL [Go to Page]
- TABLE A103.3.5 STRESS SKIN PANEL
- A103.3.6 METAL STUD WALLS [Go to Page]
- TABLE A103.3.6.1(1) OVERALL ASSEMBLY U-FACTORS FOR METAL STUD WALLS WITH CONTINUOUS INSULATION
- TABLE A103.3.6.1(2) OVERALL ASSEMBLY U-FACTORS FOR METAL STUD WALLS WITH INSULATION SUPPORTED BY Z-FURRING
- A103.3.6.1 METAL STUD WALL, OVERALL ASSEMBLY U-FACTORS
- A103.3.6.2 METAL STUD WALL, EFFECTICE R-VALUES FOR METAL FRAMING AND CAVITY ONLY [Go to Page]
- TABLE A103.3.6.2 EFFECTIVE R-VALUES FOR METAL FRAMING AND CAVITY ONLY
- A103.3.6.3 METAL BUILDING WALL [Go to Page]
- TABLE A103.3.6.3 DEFAULT METAL BUILDING WALL U-FACTORS
- A103.3.7 CONCRETE AND MASONRY WALLS [Go to Page]
- A103.3.7.1 CONCRETE MASONRY WALLS [Go to Page]
- TABLE A103.3.7.1(1) DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLS [Go to Page]
- TABLE A103.3.7.1(1)—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d, e
- TABLE A103.3.7.1(2) DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d [Go to Page]
- TABLE A103.3.7.1(2)—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d [Go to Page]
- TABLE A103.3.7.1(2)—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d [Go to Page]
- TABLE A103.3.7.1(2)—continued DEFAULT U-FACTORS FOR CONCRETE AND MASONRY WALLSa, b, c, d
- A103.3.7.2 PERIPHERAL EDGES OF INTERMEDIATE CONCRETE FLOORS [Go to Page]
- TABLE A103.3.7.2 DEFAULT U-FACTORS FOR PERIPHERAL EDGES OF INTERMEDIATE CONCRETE FLOORSa, b, c
- SECTION A104 BELOW-GRADE WALLS AND SLABS [Go to Page]
- TABLE A104.1 DEFAULT WALL U-FACTORS AND SLAB F-FACTORS FOR BASEMENTS
- A104.1 GENERAL
- A104.2 COMPONENT DESCRIPTION
- A104.3 INSULATION DESCRIPTION
- SECTION A105 FLOORS OVER UNCONDITIONED SPACE [Go to Page]
- A105.1 GENERAL [Go to Page]
- TABLE A105.1(1) DEFAULT U-FACTORS FOR FLOORS OVER VENTED CRAWLSPACE OR UNHEATED BASEMENT
- TABLE A105.1(2) DEFAULT U-FACTORS FOR FLOORS OVER HEATED PLENUM CRAWLSPACES
- TABLE A105.1(3) DEFAULT U-FACTORS FOR EXPOSED FLOORS
- A105.2 CRAWLSPACE DESCRIPTION [Go to Page]
- A105.2.1 NATURALLY VENTILATED CRAWLSPACES
- A105.2.2 MECHANICALLY VENTILATED CRAWLSPACES
- A105.2.3 HEATED PLENUM CRAWLSPACES
- A105.2.4 EXPOSED FLOORS
- A105.3 CONSTRUCTION DESCRIPTION
- SECTION A106 ON-GRADE SLAB FLOORS [Go to Page]
- A106.1 GENERAL [Go to Page]
- TABLE A106.1 DEFAULT F-FACTORS FOR ON-GRADE SLABS
- A106.2 COMPONENT DESCRIPTION
- A106.3 INSULATION DESCRIPTION
- SECTION A107 DEFAULT U-FACTORS FOR DOORS [Go to Page]
- A107.1 DOORS WITHOUT NFRC CERTIFICATION [Go to Page]
- TABLE A107.1(1) DEFAULT U-FACTORS FOR DOORS
- TABLE A107.1(2) DEFAULT U-FACTORS FOR REVOLVING DOORS
- TABLE A107.1(3) DEFAULT U-FACTORS FOR STEEL EMERGENCY DOORS
- TABLE A107.1(4) DEFAULT U-FACTORS FOR STEEL GARAGE AND HANGAR DOORS
- SECTION A108 AIR INFILTRATION [Go to Page]
- A108.1 GENERAL [Go to Page]
- TABLE A108.1(1) ASSUMED EFFECTIVE AIR CHANGES PER HOUR
- TABLE A108.1(2) DEFAULT HEAT CAPACITY/DENSITY PRODUCT FOR AIR
- APPENDIX B DEFAULT INTERNAL LOAD VALUES AND SCHEDULES [Go to Page]
- SECTION B101 GENERAL [Go to Page]
- B101.1 SCOPE
- SECTION B102 DEFAULT TABLES OF INTERNAL LOADS [Go to Page]
- B102.1 DEFAULT TABLES OF INTERNAL LOADS [Go to Page]
- TABLE B102 ACCEPTABLE OCCUPANCY DENSITIES, RECEPTACLE POWER DENSITIES AND SERVICE HOT WATER CONSUMPTIONa
- SECTION B103 DEFAULT SCHEDULES [Go to Page]
- B103.1 DEFAULT SCHEDULES [Go to Page]
- TABLE B103(1) ASSEMBLY OCCUPANCYa
- TABLE B103(2) HEALTH OCCUPANCYa
- TABLE B103(3) HOTEL/MOTEL OCCUPANCYa
- TABLE B103(4) LIGHT MANUFACTURING OCCUPANCYa
- TABLE B103(5) OFFICE OCCUPANCYa
- TABLE B103(6) PARKING GARAGE OCCUPANCYa
- TABLE B103(7) RESTAURANT OCCUPANCYa
- TABLE B103(8) RETAIL OCCUPANCYa
- TABLE B103(9) SCHOOL OCCUPANCYa
- TABLE B103(10) WAREHOUSE OCCUPANCYa
- APPENDIX C EXTERIOR DESIGN CONDITIONS [Go to Page]
- TABLE C-1 OUTDOOR DESIGN TEMPERATURES [Go to Page]
- TABLE C-1 OUTDOOR DESIGN TEMPERATURES—continued [Go to Page]
- TABLE C-1 OUTDOOR DESIGN TEMPERATURES—continued [Go to Page]