Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
NFPA 13: Automatic Sprinkler Systems Handbook, 2013
- Cover
- Copyright
- Tabke of Contents
- Preface
- Acknowledgments
- About the Contributors
- About the Editor
- PART ONE - NFPA 13, Standard for the Installation of Sprinkler Systems, with Commentary [Go to Page]
- 1 Administration [Go to Page]
- 1.1 Scope
- 1.2 Purpose
- 1.3 Application
- 1.4 Retroactivity
- 1.5 Equivalency
- 1.6 Units and Symbols
- 1.7 New Technology
- 2 Referenced Publications [Go to Page]
- 2.1 General
- 2.2 NFPA Publications
- 2.3 Other Publications
- 2.4 References for Extracts in Mandatory Sections
- 3 Definitions [Go to Page]
- 3.1 General
- 3.2 NFPA Offi cial Definitions
- 3.3 General Definitions
- 3.4 Sprinkler System Type Definitions
- 3.5 System Component Definitions
- 3.6 Sprinkler Definitions
- 3.7 Construction Definitions
- 3.8 Private Water Supply Piping Definitions
- 3.9 Storage Definitions
- 3.10 Marine Definitions
- 3.11 Hanging and Bracing Definitions
- 4 General Requirements [Go to Page]
- 4.1 Level of Protection
- 4.2 Limited Area Systems
- 4.3 Owner’s Certifi cate
- 4.4 Additives
- 4.5 Air, Nitrogen, or Other Approved Gas
- 4.6 Support of Nonsprinkler System Components
- 5 Classification of Occupancies and Commodities [Go to Page]
- 5.1 Classification of Occupancies
- 5.2 Light Hazard Occupancies
- 5.3 Ordinary Hazard Occupancies
- 5.4 Extra Hazard Occupancies
- 5.5 Special Occupancy Hazards
- 5.6 Commodity Classification
- 6 System Components and Hardware [Go to Page]
- 6.1 General
- 6.2 Sprinklers
- 6.3 Aboveground Pipe and Tube
- 6.4 Fittings
- 6.5 Joining of Pipe and Fittings
- 6.6 Hangers
- 6.7 Valves
- 6.8 Fire Department Connections
- 6.9 Waterfl ow Alarm Devices
- 6.10 Signs
- 7 System Requirements [Go to Page]
- 7.1 Wet Pipe Systems
- 7.2 Dry Pipe Systems
- 7.3 Preaction Systems and Deluge Systems
- 7.4 Combined Dry Pipe and Preaction Systems for Piers, Terminals, and Wharves
- 7.5 Multi-Cycle Systems
- 7.6 Antifreeze Systems
- 7.7 Automatic Sprinkler Systems with Non–Fire Protection Connections
- 7.8 Outside Sprinklers for Protection Against Exposure Fires (Exposure Protection Sprinkler Systems)
- 7.9 Refrigerated Spaces
- 7.10 Commercial-Type Cooking Equipment and Ventilation
- 7.11 Additives and Coatings
- 8 Installation Requirements [Go to Page]
- 8.1 Basic Requirements
- 8.2 System Protection Area Limitations
- 8.3 Use of Sprinklers
- 8.4 Application of Sprinkler Types
- 8.5 Position, Location, Spacing, and Use of Sprinklers
- 8.6 Standard Pendent and Upright Spray Sprinklers
- 8.7 Sidewall Standard Spray Sprinklers
- 8.8 Extended Coverage Upright and Pendent Spray Sprinklers
- 8.9 Extended Coverage Sidewall Spray Sprinklers
- 8.10 Residential Sprinklers
- 8.11 CMSA Sprinklers
- 8.12 Early Suppression Fast-Response Sprinklers
- 8.13 In-Rack Sprinklers
- 8.14 Pilot Line Detectors
- 8.15 Special Situations
- 8.16 Piping Installation
- 8.17 System Attachments
- 9 Hanging, Bracing, and Restraint of System Piping [Go to Page]
- 9.1 Hangers
- 9.2 Installation of Pipe Hangers
- 9.3 Protection of Piping Against Damage Where Subject to Earthquakes
- 10 Underground Piping [Go to Page]
- 10.1 Piping Materials
- 10.2 Fittings
- 10.3 Joining of Pipe and Fittings
- 10.4 Depth of Cover
- 10.5 Protection Against Freezing
- 10.6 Protection Against Damage
- 10.7 Requirement for Laying Pipe
- 10.8 Joint Restraint
- 10.9 Backfi lling
- 10.10 Testing and Acceptance
- 11 Design Approaches [Go to Page]
- 11.1 General
- 11.2 Occupancy Hazard Fire Control Approach for Spray Sprinklers
- 11.3 Special Design Approaches
- 12 General Requirements for Storage [Go to Page]
- 12.1 General
- 12.2 Hose Connections
- 12.3 Adjacent Hazards or Design Methods
- 12.4 Wet Pipe Systems
- 12.5 Dry Pipe and Preaction Systems
- 12.6 Storage Applications
- 12.7 Discharge Considerations
- 12.8 Hose Stream Allowance and Water Supply Duration
- 12.9 Restrictions
- 12.10 Room Design Method
- 12.11 High-Expansion Foam Systems
- 12.12 Protection of Idle Pallets
- 13 Miscellaneous Storage [Go to Page]
- 13.1 Miscellaneous Storage Up to 12 ft (3.7 m) in Height
- 13.2 Design Basis
- 13.3 In-Rack Sprinklers
- 14 Protection for Palletized, Solid-Piled , Bin Box, Shelf, or Back-to-Back Shelf Storage of Class I through Class IV Commodities [Go to Page]
- 14.1 General
- 14.2 Control Mode Density/Area Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Class I Through Class IV Commodities
- 14.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Class I Through Class IV Commodities
- 14.4 Early Suppression Fast-Response (ESFR) Sprinklers for Palletized or Solid-Piled Storage of Class I Through Class IV Commodities
- 14.5 Special Design for Palletized, Solid- Piled, Bin Box, or Shelf Storage of Class I Through Class IV Commodities
- 14.6 High-Expansion Foam - Reduction to Ceiling Density
- 15 Protection for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Plastic and Rubber Commodities [Go to Page]
- 15.1 General
- 15.2 Control Mode Density/Area Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to-Back Shelf Storage of Plastic and Rubber Commodities
- 15.3 CMSA Sprinklers for Palletized or Solid-Piled Storage of Plastic and Rubber Commodities
- 15.4 Early Suppression Fast-Response (ESFR) Sprinklers for Palletized or Solid-Piled Storage of Plastic and Rubber Commodities
- 15.5 High-Expansion Foam -Reduction in Ceiling Density
- 16 Protection of Rack Storage of Class I Through Class IV Commodities [Go to Page]
- 16.1 General
- 16.2 Protection Criteria for Rack Storage of Class I Through Class IV Commodities Stored Up to and Including 25 ft (7.6 m) in Height
- 16.3 Protection Criteria for Rack Storage of Class I Through Class IV Commodities Stored Over 25 ft (7.6 m) in Height
- 17 Protection of Rack Storage of Plastic and Rubber Commodities [Go to Page]
- 17.1 General
- 17.2 Protection Criteria for Rack Storage of Plastics Commodities Stored Up to and Including 25 ft (7.6 m) in Height
- 17.3 Protection Criteria for Rack Storage of Plastics Commodities Stored Over 25 ft (7.6 m) in Height
- 18 Protection of Rubber Tire Storage [Go to Page]
- 18.1 General
- 18.2 Columns Within Rubber Tire Storage
- 18.3 Water Supplies
- 18.4 Ceiling Systems
- 18.5 In-Rack Sprinkler System Requirements for Protection of Rubber Tires
- 18.6 Reduced-Discharge Density
- 19 Protection of Roll Paper [Go to Page]
- 19.1 Protection of Roll Paper Storage
- 20 Special Designs of Storage Protection [Go to Page]
- 20.1 General
- 20.2 Plastic Motor Vehicle Components
- 20.3 Sprinkler Design Criteria for Storage and Display of Class I Through Class IV Commodities, Cartoned Nonexpanded Group A Plastics and Nonexpanded Exposed Group A Plastics in Retail Stores
- 20.4 Protection of Baled Cotton Storage
- 20.5 Sprinkler Protection of Carton Records Storage with Catwalk Access
- 20.6 Compact Storage of Commodities Consisting of Paper Files, Magazines, Books, and Similar Documents in Folders and Miscellaneous Supplies with No More Than 5 Percent Plastics Up to 8 ft (2.44 m) High
- 20.7 Protection of High Bay Records Storage
- 21 Alternative Sprinkler System Designs for Chapters 12 Through 20 [Go to Page]
- 21.1 General
- 21.2 Sprinkler Protection Criteria for Palletized, Solid-Piled, Bin Box, Shelf, or Back-to- Back Shelf Storage of Class I Through Class IV and Plastic Commodities
- 21.3 Sprinkler Protection Criteria for Open-Frame Rack Storage of Class I Through Class IV and Plastic Commodities
- 21.4 Hose Stream Allowance and Water Supply Duration
- 21.5 Minimum Obstruction Criteria
- 22 Special Occupancy Requirements [Go to Page]
- 22.1 General
- 22.2 Flammable and Combustible Liquids
- 22.3 Aerosol Products
- 22.4 Spray Application Using Flammable or Combustible Materials
- 22.5 Solvent Extraction Plants
- 22.6 Installation and Use of Stationary Combustion Engines and Gas Turbines
- 22.7 Nitrate Film
- 22.8 Laboratories Using Chemicals
- 22.9 Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes
- 22.10 Acetylene Cylinder Charging Plants
- 22.11 Compressed Gases and Cryogenic Fluids Code
- 22.12 Utility LP-Gas Plants
- 22.13 Production, Storage, and Handling of Liquefied Natural Gas (LNG)
- 22.14 Protection of Information Technology Equipment
- 22.15 Standard on Incinerators, and Waste and Linen Handling Systems and Equipment
- 22.16 Standard for Ovens and Furnaces
- 22.17 Health Care Facilities Code, Hyperbaric Chambers
- 22.18 Fixed Guideway Transit and Passenger Rail Systems
- 22.19 Motion Picture and Television Production Studio Soundstages, Approved Production Facilities, and Production Locations
- 22.20 Animal Housing Facilities
- 22.21 Water Cooling Towers
- 22.22 Standard for the Construction and Fire Protection of Marine Terminals, Piers, and Wharves
- 22.23 Semiconductor Fabrication Facilities
- 22.24 Aircraft Hangars
- 22.25 Airport Terminal Buildings, Fueling Ramp Drainage, and Loading Walkways
- 22.26 Aircraft Engine Test Facilities
- 22.27 Advanced Light Water Reactor Electric Generating Plants
- 22.28 Light Water Nuclear Power Plants
- 22.29 Hydroelectric Generating Plants [NFPA 851]
- 22.30 Code for the Protection of Cultural Resource Properties - Museums, Libraries, and Places of Worship [NFPA 909]
- 22.31 National Electrical Code
- 22.32 Fire Protection of Telecommunication Facilities
- 22.33 Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids
- 22.34 Hypobaric Facilities
- 22.35 Coal Mines
- 22.36 Metal/Nonmetal Mining and Metal Mineral Processing Facilities
- 22.37 Hazardous Materials Code
- 23 Plans and Calculations [Go to Page]
- 23.1 Working Plans
- 23.2 Water Supply Information
- 23.3 Hydraulic Calculation Forms
- 23.4 Hydraulic Calculation Procedures
- 23.5 Pipe Schedules
- 23.6 Deluge Systems
- 23.7 Exposure Protection Sprinkler Systems
- 23.8 In-Rack Sprinklers
- 23.9 Hose Allowance
- 24 Water Supplies [Go to Page]
- 24.1 General
- 24.2 Types
- 25 Systems Acceptance [Go to Page]
- 25.1 Approval of Sprinkler Systems and Private Fire Service Mains
- 25.2 Acceptance Requirements
- 25.3 Circulating Closed Loop Systems
- 25.4 Instructions
- 25.5 Hydraulic Design Information Sign
- 25.6 General Information Sign
- 26 Marine Systems [Go to Page]
- 26.1 General
- 26.2 System Components, Hardware, and Use
- 26.3 System Requirements
- 26.4 Installation Requirements
- 26.5 Design Approaches
- 26.6 Plans and Calculations
- 26.7 Water Supplies
- 26.8 System Acceptance
- 26.9 System Instructions and Maintenance
- 27 System Inspection, Testing, and Maintenance [Go to Page]
- 27.1 General
- 27.2 Inactive Sprinkler Systems Abandoned in Place
- Annexes [Go to Page]
- A Explanatory Material
- B Miscellaneous Topics
- C Explanation of Test Data and Procedures for Rack Storage
- D Sprinkler System Information from the 2012 Edition of the Life Safety Code
- E Development of the Design Approach to Conform with SEI/ASCE 7
- F Informational References
- PART TWO - Supplements [Go to Page]
- 1. Evolution of Storage Sprinkler Standards
- 2. Step-by-Step Hydraulic Calculations for a Fire Sprinkler System
- 3. Technical/Substantive Changes from the 2010 to 2013 Editions of NFPA 13
- NFPA 13 Index
- Important Notices and Legal Disclaimers
- TIA 13-3 [Go to Page]