Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

2011 Orange County Utilities Standards and Construction Specifications Manual, 0
- PREFACE
- TABLE OF CONTENTS
- TABLE OF TABLES and FIGURES
- CHAPTER 1 GENERAL INFORMATION [Go to Page]
- 1110: Introduction
- 1111: Policies and Procedures
- 1112: Definitions
- 1113: Abbreviations
- CHAPTER 2 GENERAL REQUIREMENTS AND DESIGN STANDARDS [Go to Page]
- 2110: General Submittal Requirements
- 2111: Project Documents and Submittals
- 2112: Aerial Crossings
- 2113: Directional Drilling
- 2114: Jack and Bore
- 2210: Water Main Design Standard
- 2310: Gravity Main Design Standard
- 2311: Wastewater Force Main Design Standard
- 2410: Wastewater Pump Station Design Standard
- 2510: Reclaimed Water Main Design Standard
- CHAPTER 3 SPECIFICATIONS [Go to Page]
- 3110: General Construction Requirements
- 3111: Project Record Documents and Submittals
- 3112: Site Preparations, Surface Removal, and Restoration
- 3113: Excavations, Backfill, Compaction and Grading
- 3114: Installation of Pipe
- 3115: Directional Drilling
- 3116: Jack and Bore
- 3117: System Connections
- 3118: Aerial Crossings
- 3119: Coatings and Linings
- 3210: Water Pipes, Valves, and Appurtenances
- 3310: Wastewater Pipes, Valves, and Appurtenances
- 3311: Wastewater Manholes
- 3312: Collection System Bypass
- 3410: Wastewater Pump Stations
- 3411: Submersible Wastewater Pumps
- 3412: Wastewater Pump Station Electrical Power & Control System
- 3413: SCADA RTU Panel
- 3510: Reclaimed water Pipes, Valves, and Appurtenances
- 3511: Reclaimed Water Master Meter Electrical Control Systems
- CHAPTER 4 FIELD TESTING AND INSPECTION PROCEDURES [Go to Page]
- 4110: General Procedures
- 4210: Testing and Inspection for Acceptance of Water Systems
- 4310: Testing & Inspection for Acceptance of Wastewater Collection and Transmission Systems
- 4410: Testing & Inspection for Acceptance of Pump Stations
- 4510: Testing & Inspection for Acceptance of Reclaimed Water Systems
- APPENDIX A STANDARD DRAWINGS [Go to Page]
- GENERAL [Go to Page]
- FigGN
- FigA101
- FigA102
- figA103
- FigA104-1
- FigA104-2
- figA105-1
- figA105-2
- FigA106
- FigA107
- FigA108
- FigA109
- FigA110
- FigA111
- FigA112
- FigA113
- FigA114
- FigA115-1
- FigA115-2
- FigA115-3
- FigA116
- FigA117
- FigA118
- FigA119
- FigA120
- FigA121-1
- FigA121-2
- FigA122-1
- FigA122-2
- FigA122-3
- WATER DISTRIBUTION [Go to Page]
- FigA201
- FigA202
- FigA203
- FigA204
- FigA205
- WASTEWATER COLLECTION [Go to Page]
- FigA301
- FigA302
- FigA303
- FigA304
- FigA305
- FigA306
- figA307-1
- FigA307-2
- WASTEWATER PUMP STATIONS [Go to Page]
- FigA401
- FigA402-1
- FigA402-2
- FigA402-3
- FigA402-4
- FigA402-5
- FigA402-6
- FigA403-1
- FigA403-2
- FigA403-3
- FigA403-4
- FigA403-5
- FigA403-6
- FigA404-1
- FigA404-2
- FigA404-3
- FigA404-4
- FigA404-5
- FigA405
- FigA406
- FigA407-1
- FigA407-2
- FigA408
- FigA409
- FigA412
- FigA413-1
- FigA413-2
- FigA414
- FigA415-1
- FigA415-2
- FigA416
- FigA417
- FigA418
- FigA419-1
- FigA419-2
- FigA419-3
- FigA419-4
- FigA420
- RECLAIMED WATER DISTRIBUTION [Go to Page]
- FigA501
- FigA502
- FigA503
- APPENDIX B FORMS [Go to Page]
- Pump Station Start-Up
- Water Main Disinfection Certification
- System Connection
- Pressure Test
- Conveyance of Easement and Fee Simple Property
- Bill of Sale (Water and Water Reclamation Systems)
- Digital Data Submission
- APPENDIX D PRODUCTS [Go to Page]
- Approval Process for New Products
- General Information
- LIST OF APPROVED PRODUCTS - TRANSMISSION SYSTEMS
- LIST OF APPROVED PRODUCTS - GRAVITY SYSTEMS
- LIST OF APPROVED PRODUCTS - PUMP STATION SYSTEMS
- APPENDIX E ERU/ERC FACTORS [Go to Page]