Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS ISO 23475-1:2021 Testing method for steel tyre cord - General requirements, 2021
- National foreword
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Dimension [Go to Page]
- 4.1 Cord diameter [Go to Page]
- 4.1.1 Measure with micrometre
- 4.1.2 Measure with profile projector
- 4.2 Unravelled filament diameter [Go to Page]
- 4.2.1 Principle
- 4.2.2 Apparatus
- 4.2.3 Procedure
- 4.2.4 Expression of results
- 4.2.5 Test report
- 4.3 Linear density [Go to Page]
- 4.3.1 Principle
- 4.3.2 Apparatus
- 4.3.3 Procedure
- 4.3.4 Test report
- 4.4 Lay direction and lay length [Go to Page]
- 4.4.1 Lay direction/direction of lay
- 4.4.2 Trace method for lay length
- 4.4.3 Untwisting method for lay length
- 5 Process property [Go to Page]
- 5.1 Straightness [Go to Page]
- 5.1.1 Principle
- 5.1.2 Apparatus
- 5.1.3 Procedure
- 5.1.4 Test report
- 5.2 Arc height [Go to Page]
- 5.2.1 Principle
- 5.2.2 Apparatus
- 5.2.3 Procedure
- 5.2.4 Test report
- 5.3 Flare [Go to Page]
- 5.3.1 Principle
- 5.3.2 Apparatus
- 5.3.3 Procedure
- 5.3.4 Test report
- 5.4 Residual torsion [Go to Page]
- 5.4.1 Principle
- 5.4.2 Apparatus
- 5.4.3 Procedure
- 5.4.4 Test report
- 6 Mechanical property [Go to Page]
- 6.1 Breaking load and elongation at fracture [Go to Page]
- 6.1.1 Principle
- 6.1.2 Apparatus
- 6.1.3 Procedure
- 6.1.4 Test report
- 6.2 Elongation between defined forces (EDF) [Go to Page]
- 6.2.1 Principle
- 6.2.2 Apparatus
- 6.2.3 Procedure
- 6.2.4 Test report
- 6.3 Loop test (Elasticity) [Go to Page]
- 6.3.1 Principle
- 6.3.2 Apparatus
- 6.3.3 Procedure
- 6.3.4 Test report
- 7 Determination of mass and composition of coating by X-Ray fluorescence spectroscopy [Go to Page]
- 7.1 Principle
- 7.2 Apparatus [Go to Page]
- 7.2.1 WDXRFS or EDXRFS
- 7.2.2 Analytical balance, which can be read to the nearest 0,001 g.
- 7.2.3 Dispenser, with the accuracy of 25,00 ml ± 0,05 ml.
- 7.2.4 X/Y shaker, with variable frequency.
- 7.3 Reagents [Go to Page]
- 7.3.1 Acetone or diethyl ether
- 7.3.2 Ammonium persulphate (mass fraction >98 %)
- 7.3.3 Ammonia (mass fraction >25 %, not more than “d=0,91” at temperature 20 °C)
- 7.3.4 Stripping solution, for 1 l: weigh 16 g ammonia persulphate into a beaker of 600 ml and dissolve in 400 ml demineralized water. Transfer quantitatively into a 1 l volumetric flask. Add 120 ml ammonia. Fill up to the mark with demineralized water. Sh
- 7.3.5 Standard, the matrix and range should cover the sample range. Prepare the calibration standards according to the XRFS user’s manual or according to an example in Table 1.
- 7.4 Preparation of test samples
- 7.5 Procedure
- 7.6 Expression of results
- 7.7 Test report [Go to Page]