Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

BS EN IEC 61000-6-8:2020 Electromagnetic compatibility (EMC) - Generic standards. Emission standard for professional equipment in commercial and light-industrial locations, 2020
- undefined
- Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms [Go to Page]
- 3.1 Terms and definitions
- Figures [Go to Page]
- Figure 1 – Example of ports
- 3.2 Abbreviated terms
- 4 Classification of equipment
- 5 Measurements and conditions during testing
- 6 Documentation for the user
- Tables [Go to Page]
- Table 1 – Test arrangements of EUT
- 7 Applicability
- 8 Emission requirements
- 9 Measurement uncertainty
- 10 Compliance with this document
- 11 Emission test requirements [Go to Page]
- Table 2 – Required highest frequency for radiated measurement
- Table 3 – Requirements for radiated emissions – Enclosure port
- Table 4 – Requirements for conducted emissions – Low voltage AC mains port
- Table 5 – Requirements for conducted emissions – DC power port
- Table 6 – Requirements for conducted emissions, other wires ports
- Annex A (informative)Examples of emission classification of equipment and mapping to the immunity standard [Go to Page]
- Table A.1 – Examples of emission classification of equipment to immunity standard against product type and its intended environment
- Annex B (normative)Testing of DC powered systems [Go to Page]
- Table B.1 – Conducted testing requirements of DC powered equipment
- Table B.2 – Conditional requirements for the start frequency of test at DC power ports for tests defined in table clause B1.4 to B1.7
- Annex C (informative)Rationale for alternative test levels at the DC power port [Go to Page]
- C.1 General
- C.2 Necessity of alternative test methods in generic standards
- C.3 Limit justification in table clause 5.2 [Go to Page]
- C.3.1 Proportional relation approach
- C.3.2 Current-to-voltage conversion approach
- Figure C.1 – Equivalent circuit of test set-up for measurement of disturbance voltages
- Table C.1 – DC power port, terminal disturbance voltage limits for class A GCPCs, measured on a test site, proportion relation approach [Go to Page]
- C.3.3 Setting the final limit
- Figure C.2 – Limit proposals of the two different approach and the final limit compromise
- Table C.2 – DC power port, terminal disturbance voltage limits for class A GCPCs, measured on a test site, current-to-voltage conversion approach
- Table C.3 – DC power port, terminal disturbance voltage limits for class A GCPCs, with rated throughput ≤ 20 kVA
- Annex D (informative)Special measures and mitigation techniques [Go to Page]
- Table D.1 – Examples of special measures and mitigation techniques, for the enclosure port
- Table D.2 – Examples of special measures and mitigation techniques, for the various wired ports
- Bibliography [Go to Page]