Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN 81-40:2020 Safety rules for the construction and installation of lifts. Special lifts for the transport of persons and goods - Stairlifts and inclined lifting platforms intended for persons with impaired mobility, 2020
- undefined
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 List of significant hazards
- 5 Safety requirements and/or protective measures [Go to Page]
- 5.1 General [Go to Page]
- 5.1.1 Introduction
- 5.1.2 Pattern of use
- 5.1.3 Access for maintenance, repair and inspection
- 5.1.4 Fire resistance
- 5.1.5 Speed
- 5.1.6 Rated load [Go to Page]
- 5.1.6.1 General
- 5.1.6.2 Load control
- 5.1.7 Resistance to operating forces
- 5.1.8 Protection of equipment against harmful external influences [Go to Page]
- 5.1.8.1 General
- 5.1.8.2 Degree of protection for outdoor use
- 5.1.9 Guarding of equipment from mechanical damage
- 5.2 Guide rails and mechanical stops [Go to Page]
- 5.2.1 Guide rails
- 5.2.2 Folding guide rails
- 5.2.3 Stairlift guide rail
- 5.2.4 Rail design
- 5.3 Safety gear and overspeed detection device [Go to Page]
- 5.3.1 General
- 5.3.2 Control
- 5.3.3 Release
- 5.3.4 Access for inspection
- 5.3.5 Electrical checking
- 5.3.6 Overspeed detection device
- 5.3.7 Rotation monitor unit
- 5.4 Driving units and drive system [Go to Page]
- 5.4.1 General requirements
- 5.4.2 Braking system [Go to Page]
- 5.4.2.1 General
- 5.4.2.2 Electro-mechanical brake
- 5.4.3 Emergency/manual operation
- 5.4.4 Additional requirements for rope suspension drive [Go to Page]
- 5.4.4.1 Ropes
- 5.4.4.2 Winding drum
- 5.4.4.3 Pulleys and diverter pulleys
- 5.4.4.4 Angle of deflection
- 5.4.5 Additional requirements for rack and pinion drive [Go to Page]
- 5.4.5.1 Driving pinion
- 5.4.5.2 Driving rack(s)
- 5.4.6 Additional requirements for chain suspension drive [Go to Page]
- 5.4.6.1 General
- 5.4.6.2 Sprockets
- 5.4.6.3 Chains
- 5.4.6.4 Protection and guarding
- 5.4.7 Additional requirements for friction/traction drive [Go to Page]
- 5.4.7.1 Traction wheels
- 5.4.7.2 Running surface
- 5.4.7.3 Traction
- 5.4.8 Additional requirements for guided rope and ball drive [Go to Page]
- 5.4.8.1 General
- 5.4.8.2 Drive sprocket
- 5.4.8.3 Rail design
- 5.4.8.4 Slack rope
- 5.4.8.5 Protection and guarding
- 5.5 Electrical installation and equipment [Go to Page]
- 5.5.1 General
- 5.5.2 Drive contactors
- 5.5.3 Motor and brake circuits for stopping the machine and checking its stopped condition [Go to Page]
- 5.5.3.1 Motors supplied directly from AC mains
- 5.5.3.2 AC or DC motors controlled and supplied by solid state elements
- 5.5.3.3 Interruption of the electrical supply
- 5.5.4 Creepage and clearance distances and enclosure requirements [Go to Page]
- 5.5.4.1 Enclosure requirements
- 5.5.4.2 Creepage and clearance distances
- 5.5.5 Protection against electrical faults
- 5.5.6 Electric safety devices
- 5.5.7 Time delay
- 5.5.8 Protection of the driving motor
- 5.5.9 Electrical wiring [Go to Page]
- 5.5.9.1 Conductors, insulation and earth bonding
- 5.5.9.2 Insulation
- 5.5.9.3 Flexible cables
- 5.5.9.4 Continuity conductors
- 5.5.9.5 Nut or screw
- 5.5.9.6 Earth bonding
- 5.5.9.7 Terminals and connectors
- 5.5.10 Safety circuits
- 5.5.11 Residual current devices
- 5.5.12 Additional requirements for battery powered operation
- 5.5.13 Cableless controls
- 5.5.14 Control devices
- 5.5.15 Terminal limit switches and final limit electric safety devices
- 5.5.16 Emergency alarm devices and warning signals [Go to Page]
- 5.5.16.1 Two-way voice communication device
- 5.5.16.2 Warning signals
- 5.6 Carriage [Go to Page]
- 5.6.1 Combined type of carriage
- 5.6.2 Chair [Go to Page]
- 5.6.2.1 General
- 5.6.2.2 Height above stairway
- 5.6.2.3 Safety belt/restraint
- 5.6.2.4 Sliding or rotating seats
- 5.6.2.5 Sensitive edges and surfaces
- 5.6.2.6 Chair levelling system
- 5.6.3 Carriage with standing platform [Go to Page]
- 5.6.3.1 Standing platforms
- 5.6.3.2 Barrier arm
- 5.6.3.3 Barrier locking
- 5.6.3.4 Height above floor level
- 5.6.3.5 Sensitive edges and surfaces
- 5.6.4 Carriage with wheelchair platform [Go to Page]
- 5.6.4.1 Floor covering
- 5.6.4.2 Rated load and platform size
- 5.6.4.3 Folding platforms
- 5.6.4.4 Ramps and toe-guards
- 5.6.4.5 Platform side protection
- 5.6.4.6 Barrier arms and ramp electric safety devices and locks
- 5.6.4.7 Barrier locking
- 5.6.4.8 Emergency unlocking
- 5.6.4.9 Sensitive edges and surfaces
- 5.6.4.10 Emergency operation of a hinged platform
- 5.6.4.11 Tip-up seats
- 5.6.4.12 Boarding point control positions
- 6 Verification of safety requirements and/or protective measures [Go to Page]
- 6.1 General
- 6.2 Verification of design
- 6.3 Verification tests [Go to Page]
- 6.3.1 General
- 6.3.2 Overspeed safety device and safety gear
- 6.3.3 Chair levelling safety device
- 6.3.4 Verification tests for static overload
- 6.3.5 Self-sustaining system
- 6.3.6 Safety circuits containing electronic components
- 6.3.7 Safety surfaces and edges
- 6.4 Verification tests on each machine before first use [Go to Page]
- 6.4.1 Verification test at completion of installation
- 6.4.2 Documentation
- 7 Information for use [Go to Page]
- 7.1 General
- 7.2 Signals and warning devices
- 7.3 Accompanying documents (in particular: Instruction handbook) [Go to Page]
- 7.3.1 General
- 7.3.2 Sales literature
- 7.4 Marking [Go to Page]
- 7.4.1 Carriage
- 7.4.2 Emergency alarm device
- 7.4.3 Disabled persons symbol
- 7.4.4 Emergency manual operation
- 7.4.5 Electrical supply
- Annex A (normative)Verification tests – Seat and safety components – tests procedures for verification of conformity [Go to Page]
- A.1 Instruments
- A.2 Safety gear and overspeed detection device type test [Go to Page]
- A.2.1 General provisions
- A.2.2 Method of test [Go to Page]
- A.2.2.1 The tests shall be conducted at the detection device tripping speed specified by the manufacturer (not more than 0,3 m/s).
- A.2.2.2 The total number of repeated tests shall be not less than 20. At least there shall be:
- A.2.2.3 Relevant direct or indirect measurements shall be made to determine the average stopping distance or average deceleration:
- A.2.2.4 The following shall be checked after each series of tests:
- A.2.2.5 One test with rated load plus 25 % overload, drive disengaged, at maximum angle, there shall be no cracks or permanent deformation.
- A.2.3 Test report
- A.3 Static overload verification tests [Go to Page]
- A.3.1 Calculation of worst-case loads
- A.3.2 Method of test
- A.4 Verification test for chair levelling safety device [Go to Page]
- A.4.1 General
- A.4.2 Method of test [Go to Page]
- A.4.2.1 The tests shall be conducted as follows:
- A.4.2.2 The tests shall consist of at least:
- A.4.2.3 Relevant direct or indirect measurements shall be made before and after the tests to determine the chair angle.
- A.4.2.4 The following shall be checked after each test:
- A.5 Verification tests of edges and surfaces
- A.6 Verification tests for self-sustaining system
- Annex B (normative)Electronic components: failure exclusion
- Annex C (normative)Requirements for the interface of the stairlift in the building [Go to Page]
- C.1 Minimum clearances to adjacent surfaces
- C.2 Minimum clearances to bulkheads and other overhead obstacles
- C.3 Means of escape in case of fire
- C.4 Electrical supply and lighting
- Annex D (informative)Guidance in selection of stairlifts [Go to Page]
- D.1 General
- D.2 Selection of stairlift [Go to Page]
- D.2.1 Suitability [Go to Page]
- D.2.1.1 Seated stairlifts and standing platforms are not suitable for use in public situations.
- D.2.1.2 When selecting a stairlift, the user’s abilities shall be taken into account and both the existing and future needs of the user should be considered.
- D.2.1.3 A stairlift should be selected with a rated load that is capable of carrying the maximum foreseeable load.
- D.2.1.4 Where either manual or automatic operation are optionally available for devices such as barriers, consider which is more appropriate for the user.
- D.2.2 Control devices
- D.2.3 Location of the stairlift
- D.2.4 Duty cycle
- D.3 Maintenance
- Annex E (informative)Recommendations for the provisions and use of specially adapted control devices, switches and sensors [Go to Page]
- E.1 Control devices
- E.2 Specially adapted switches
- Annex F (informative)In-use periodic examination, tests and servicing [Go to Page]
- F.1 Periodic examinations and tests
- F.2 Servicing
- Annex G (normative)Friction/traction drive – Calculation and test for verification of traction conformity
- Annex ZA(informative)Relationship between this European Standard and the essential requirements of Directive 2006/42/EC aimed to be covered [Go to Page]