Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN 60079-17:2014 Explosive atmospheres - Electrical installations inspection and maintenance, 2014
- 30294322-VOR.pdf [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements [Go to Page]
- 4.1 Documentation
- 4.2 Qualification of personnel
- 4.3 Inspections [Go to Page]
- 4.3.1 General
- 4.3.2 Grades of inspection
- 4.3.3 Types of inspection
- 4.4 Periodic inspections [Go to Page]
- 4.4.1 Personnel
- 4.4.2 Fixed installations
- 4.4.3 Movable equipment
- 4.5 Continuous supervision by skilled personnel [Go to Page]
- 4.5.1 Concept
- 4.5.2 Objectives
- 4.5.3 Responsibilities
- 4.5.4 Frequency of inspection
- 4.5.5 Documents
- 4.5.6 Training
- 4.6 Maintenance requirements [Go to Page]
- 4.6.1 Remedial measures and alterations to equipment
- 4.6.2 Maintenance of flexible cables
- 4.6.3 Withdrawal from service
- 4.6.4 Fastenings and tools
- 4.7 Environmental conditions
- 4.8 Isolation of equipment [Go to Page]
- 4.8.1 Installations other than intrinsically safe circuits
- 4.8.2 Intrinsically safe installations live maintenance
- 4.9 Earthing and equipotential bonding
- 4.10 Specific conditions of use
- 4.11 Movable equipment and its connections
- 4.12 Inspection schedules (Tables 1 to 3) [Go to Page]
- 4.12.1 General
- 4.12.2 Equipment is appropriate to the EPL/zone requirements of the location
- 4.12.3 Equipment group
- 4.12.4 Equipment maximum surface temperature
- 4.12.5 Equipment circuit identification
- 4.12.6 Cable gland
- 4.12.7 Type of cable
- 4.12.8 Sealing
- 4.12.9 Fault loop impedance or earthing resistance
- 4.12.10 Insulation resistance
- 4.12.11 Overload protection
- 4.12.12 Lamps and luminaires
- 5 Additional inspection schedule requirements [Go to Page]
- 5.1 Type of protection “d” – Flameproof enclosure (see Table 1 and IEC 60079-1)
- 5.2 Type of protection “e” – Increased safety (see Table 1 and IEC 60079-7)
- 5.3 Type of protection “i” – Intrinsic safety (see Table 2 and IEC 60079-11) [Go to Page]
- 5.3.1 General
- 5.3.2 Documentation
- 5.3.3 Labelling
- 5.3.4 Unauthorized modifications
- 5.3.5 Associated apparatus (safety interface) between intrinsically safe and non-intrinsically safe circuits
- 5.3.6 Cables
- 5.3.7 Cable screens
- 5.3.8 Point-to-point connections
- 5.3.9 Earth continuity of non-galvanically isolated circuits
- 5.3.10 Earth connections to maintain the integrity of the intrinsic safety
- 5.3.11 Intrinsically safe circuit earthing and/or insulation
- 5.3.12 Separation between intrinsically safe and non-intrinsically safe circuits
- 5.4 Type of protection “p” and “pD” – Pressurized enclosure (see Table 3, IEC 600792 and IEC 61241-4)
- 5.5 Type of protection “n” (see Table 1 or 2 and IEC 60079-15) [Go to Page]
- 5.5.1 General
- 5.5.2 Restricted breathing enclosures
- 5.6 Type of protection “t” and “tD” – Protection by enclosure (see Table 1 and IEC 60079-31 and IEC 61241-1)
- 5.7 Types of protection “m” and “mD” (encapsulation), “o”, (oil-immersion) “op” (optical radiation) and “q” (powder-filling)
- 6 Inspection tables
- Annex A (informative)Typical inspection procedure for periodic inspections
- Annex B (normative)Knowledge, skills and competencies of responsible persons,technical persons with executive function and operatives [Go to Page]
- B.1 Scope
- B.2 Knowledge and skills [Go to Page]
- B.2.1 Responsible persons and technical persons with executive function
- B.2.2 Operative/technician (inspection and maintenance)
- B.3 Competencies [Go to Page]
- B.3.1 General
- B.3.2 Responsible persons and technical persons with executive function
- B.3.3 Operative/technician
- B.4 Assessment
- Annex C (informative)Fitness-for-purpose assessment [Go to Page]
- C.1 Background
- C.2 Need for a fitness-for-purpose assessment
- C.3 Approach
- C.4 Ignition sources
- C.5 Contents of the fitness-for-purpose assessment [Go to Page]
- C.5.1 General
- C.5.2 Scope
- C.5.3 Equipment and its application
- C.5.4 Description
- C.5.5 Function of the product including the location
- C.5.6 Specification
- C.5.7 Standards compliance
- C.5.8 Documents
- C.5.9 Product sample
- C.5.10 Equipment label
- C.5.11 Training of personnel
- Annex D (informative)Example of motor checks
- Bibliography
- Figure A.1 – Typical inspection procedure for periodic inspections
- Table 1 – Inspection schedule for Ex “d”, Ex “e”, Ex “n” and Ex “t/tD”
- Table 2 – Inspection schedule for Ex “i” installations
- Table 3 – Inspection schedule for Ex “p” and “pD” installations
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Exigences générales [Go to Page]
- 4.1 Documentation
- 4.2 Qualification du personnel
- 4.3 Inspections [Go to Page]
- 4.3.1 Généralités
- 4.3.2 Degrés d’inspection
- 4.3.3 Types d’inspection
- 4.4 Inspections périodiques [Go to Page]
- 4.4.1 Personnel
- 4.4.2 Installations fixes
- 4.4.3 Matériel amovible
- 4.5 Surveillance continue par un personnel qualifié [Go to Page]
- 4.5.1 Concept
- 4.5.2 Objectifs
- 4.5.3 Responsabilités
- 4.5.4 Fréquence des inspections
- 4.5.5 Documents
- 4.5.6 Formation
- 4.6 Exigences relatives à l’entretien [Go to Page]
- 4.6.1 Remise en ordre et modifications des matériels
- 4.6.2 Entretien des câbles flexibles
- 4.6.3 Mise hors service
- 4.6.4 Fermetures et outils
- 4.7 Conditions d’environnement
- 4.8 Isolation du matériel [Go to Page]
- 4.8.1 Installations autres que les circuits de sécurité intrinsèque
- 4.8.2 Installations de sécurité intrinsèque (Entretien sous tension)
- 4.9 Mise à la terre et liaisons équipotentielles
- 4.10 Conditions particulières d’utilisation
- 4.11 Matériels amovibles et leurs connexions
- 4.12 Programmes d’inspection (Tableaux 1 à 3) [Go to Page]
- 4.12.1 Généralités
- 4.12.2 Matériel approprié au niveau de protection/aux exigences de la zone concernée
- 4.12.3 Groupe de matériel
- 4.12.4 Température de surface maximale du matériel
- 4.12.5 Identification du circuit du matériel
- 4.12.6 Presse-étoupe
- 4.12.7 Type de câble
- 4.12.8 Obturation
- 4.12.9 Impédance de la boucle de défaut ou résistance de terre
- 4.12.10 Résistance d'isolement
- 4.12.11 Protection contre la surcharge
- 4.12.12 Lampes et luminaires
- 5 Exigences complémentaires pour les programmes d’inspection [Go to Page]
- 5.1 Mode de protection “d” – Enveloppe antidéflagrante (voir Tableau 1 et CEI 60079-1)
- 5.2 Mode de protection “e” – Sécurité augmentée (voir Tableau 1 et CEI 60079-7)
- 5.3 Mode de protection “i” – Sécurité intrinsèque (voir Tableau 2 et CEI 60079-11 [Go to Page]
- 5.3.1 Généralités
- 5.3.2 Documentation
- 5.3.3 Etiquetage
- 5.3.4 Modifications non autorisées
- 5.3.5 Matériel associé (interface de sécurité) entre les circuits de sécurité intrinsèque et les circuits de sécurité non intrinsèque
- 5.3.6 Câbles
- 5.3.7 Écrans des câbles
- 5.3.8 Connexions point à point
- 5.3.9 Continuité de la liaison à la terre de circuits non isolés galvaniquement
- 5.3.10 Connexions de mise à la terre assurant l'intégrité de la sécurité intrinsèque
- 5.3.11 Mise à la terre et/ou isolation des circuits de sécurité intrinsèque
- 5.3.12 Séparation entre circuits de sécurité intrinsèque et circuits de sécurité non intrinsèque
- 5.4 Modes de protection “p” et “pD” – Enveloppe à surpression interne (voir Tableau 3; CEI 600792 et CEI 61241-4)
- 5.5 Mode de protection “n” (voir Tableau 1 ou 2 et CEI 60079-15) [Go to Page]
- 5.5.1 Généralités
- 5.5.2 Enveloppes à respiration limitée
- 5.6 Mode de protection "t" et "tD"– Protection par enveloppes (voir Tableau 1 et CEI 60079-31 et CEI 61241-1)
- 5.7 Modes de protection “m” et “mD” (encapsulage), “o” (immersion dans l’huile), "op" (rayonnement optique) et “q” (remplissage pulvérulent)
- 6 Tableaux d'inspection
- Annexe A (informative)Procédure type d'inspection pour les inspections périodiques
- Annexe B (normative)Connaissances, compétences et qualifications des “personnes responsables”, “personnes avec qualification technique ayant une fonction d’encadrement” et “opérateurs” [Go to Page]
- B.1 Domaine d'application
- B.2 Connaissances et compétences [Go to Page]
- B.2.1 Personnes responsables et personnes avec qualification technique ayant une fonction d’encadrement
- B.2.2 Opérateurs/Techniciens (inspection et entretien)
- B.3 Qualifications [Go to Page]
- B.3.1 Généralités
- B.3.2 Personnes responsables et personnes avec qualification technique ayant une fonction d’encadrement
- B.3.3 Opérateurs/Techniciens
- B.4 Evaluation
- Annexe C (informative)Évaluation de l’aptitude à l’usage [Go to Page]
- C.1 Historique
- C.2 Nécessité d’une évaluation de l’aptitude à l’usage
- C.3 Approche
- C.4 Sources d’inflammation
- C.5 Contenu de l’évaluation de l’aptitude à l’usage [Go to Page]
- C.5.1 Généralités
- C.5.2 Domaine d’application
- C.5.3 Matériel et application
- C.5.4 Description
- C.5.5 Fonction du produit comprenant l’emplacement
- C.5.6 Spécification
- C.5.7 Conformité aux normes
- C.5.8 Documents
- C.5.9 Echantillon de produit
- C.5.10 Etiquette de matériel
- C.5.11 Formation du personnel
- Annexe D (informative) Exemple de vérifications de moteur
- Bibliographie
- Figure A.1 – Procédure type d'inspection pour les inspections périodiques
- Tableau 1 – Programme d’inspection pour les installationsEx “d”, Ex “e”, Ex “n” et Ex “t/tD”
- Tableau 2 – Programme d’inspection pour les installations Ex “i”
- Tableau 3 – Programme d’inspection pour les installations Ex “p” et “pD” [Go to Page]