Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN 13216-1:2019 Chimneys. Test methods for system chimneys - General test methods, 2019
- undefined
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test environment [Go to Page]
- 4.1 Location of test assembly
- 4.2 Conditions of the test environment
- 4.3 Measurement of ambient air temperature and atmospheric pressure
- 4.4 Accuracy of measurement
- 5 Performance tests for system chimneys [Go to Page]
- 5.1 General
- 5.2 Abrasion resistance test [Go to Page]
- 5.2.1 Test apparatus
- 5.2.2 Test sample
- 5.2.3 Measuring parameters
- 5.2.4 Test procedure
- 5.2.5 Test results
- 5.3 Test of the relative movement of the flue liner in multi-wall system chimneys [Go to Page]
- 5.3.1 Test apparatus
- 5.3.2 Test sample
- 5.3.3 Measuring parameters
- 5.3.4 Test procedure
- 5.3.5 Test results
- 5.4 Gas tightness test [Go to Page]
- 5.4.1 Test apparatus
- 5.4.2 Test sample
- 5.4.3 Measuring parameters
- 5.4.4 Test procedure
- 5.4.5 Test results
- 5.5 Condensate penetration test (liquid phase) [Go to Page]
- 5.5.1 Test apparatus
- 5.5.2 Test sample
- 5.5.3 Measuring parameters
- 5.5.4 Test procedure
- 5.5.5 Test results
- 5.6 Condensate resistance test (vapour phase) [Go to Page]
- 5.6.1 Test apparatus
- 5.6.2 Test sample
- 5.6.3 Measuring parameters [Go to Page]
- 5.6.3.1 General
- 5.6.3.2 Ambient air temperature and humidity
- 5.6.3.3 Flue gas temperature and humidity
- 5.6.3.4 Layer temperatures
- 5.6.3.5 Layer humidity
- 5.6.3.6 Change in weight
- 5.6.3.7 Location for surface temperature and humidity/temperature measurements
- 5.6.3.8 Chimney draught measurement
- 5.6.3.9 Flue gas velocity
- 5.6.3.10 Test environment, test room
- 5.6.4 Test procedure
- 5.6.5 Test results
- 5.7 Thermal performance test [Go to Page]
- 5.7.1 General
- 5.7.2 Test assembly [Go to Page]
- 5.7.2.1 General
- 5.7.2.2 Test structure parameters
- 5.7.2.3 Test sample
- 5.7.2.4 Test apparatus
- 5.7.2.5 Measurement equipment and parameter (including location of sensors)
- 5.7.3 Test procedure [Go to Page]
- 5.7.3.1 General
- 5.7.3.2 Test procedure for normal working conditions
- 5.7.3.3 Test procedure for sootfire conditions
- 5.7.4 Test results
- 5.8 Thermal resistance test [Go to Page]
- 5.8.1 Test apparatus
- 5.8.2 Test sample
- 5.8.3 Measuring parameters
- 5.8.4 Test procedure [Go to Page]
- 5.8.4.1 Heat input with the test sample
- 5.8.4.2 Heat input without the test sample
- 5.8.5 Test results
- 5.9 Terminal flow resistance for terminal Type I, II and III [Go to Page]
- 5.9.1 General
- 5.9.2 Test apparatus
- 5.9.3 Test sample
- 5.9.4 Measurement parameters
- 5.9.5 Test condition
- 5.9.6 Test procedure
- 5.9.7 Test result
- 5.9.8 Flow resistance in the flue duct for terminals Type I, II and III
- 5.9.9 Flow resistance in the air duct for terminals Type III
- 5.10 Aerodynamic behaviour of terminal under wind conditions [Go to Page]
- 5.10.1 For terminal Type II, test method for wind velocity pressure [Go to Page]
- 5.10.1.1 Test apparatus
- 5.10.1.2 Test sample
- 5.10.1.3 Measurement parameters
- 5.10.1.4 Test condition
- 5.10.1.5 Test procedure
- 5.10.1.6 Test result
- 5.10.1.7 Wind velocity pressure of a terminal Type II – for non-room-sealed and room-sealed appliances
- 5.10.2 For a terminal Type III, test method for wind velocity pressure [Go to Page]
- 5.10.2.1 Test apparatus
- 5.10.2.2 Test sample
- 5.10.2.3 Measurement parameters
- 5.10.2.4 Test condition
- 5.10.2.5 Test procedure
- 5.10.2.6 Test result
- 5.10.2.7 Wind velocity pressure of a terminal, Type III – for balanced flue applications
- 5.10.3 For terminal Type III, test method for recirculation [Go to Page]
- 5.10.3.1 Test apparatus
- 5.10.3.2 Test sample
- 5.10.3.3 Measurement parameters
- 5.10.3.4 Test condition
- 5.10.3.5 Test procedure
- 5.10.3.6 Test result
- 5.10.3.7 Recirculation factor of a terminal, Type III, (for room sealed appliances)
- 5.11 Flow resistance of the test chimney, of fittings or liners [Go to Page]
- 5.11.1 Test apparatus
- 5.11.2 Test sample
- 5.11.3 Measuring parameter
- 5.11.4 Test procedure
- 5.11.5 Test results
- 5.12 Rainwater resistance of chimney sections [Go to Page]
- 5.12.1 Test apparatus
- 5.12.2 Test sample
- 5.12.3 Measuring parameters
- 5.12.4 Test procedure
- 5.12.5 Test results
- 5.13 Freeze–thaw resistance [Go to Page]
- 5.13.1 Apparatus
- 5.13.2 Test samples
- 5.13.3 Test procedure [Go to Page]
- 5.13.3.1 Immersion of test samples in a water bath
- 5.13.3.2 Determination of water absorption
- 5.13.3.3 Freeze–thaw cycling
- 5.13.3.4 Evaluation of test results
- 5.13.4 Test result
- 5.14 Rainwater ingress for terminals [Go to Page]
- 5.14.1 General
- 5.14.2 For terminal Type Ib, II and III, test method without wind [Go to Page]
- 5.14.2.1 Test apparatus
- 5.14.2.2 Test sample
- 5.14.2.3 Measuring parameters
- 5.14.2.4 Test condition
- 5.14.2.5 Test procedure
- 5.14.2.6 Test result
- 5.14.3 For terminal Type Ib, II and III, test method with wind [Go to Page]
- 5.14.3.1 Test apparatus
- 5.14.3.2 Test sample
- 5.14.3.3 Measurement parameters
- 5.14.3.4 Test condition
- 5.14.3.5 Test procedure
- 5.14.3.6 Test result
- 5.15 Icing behaviour, test method for terminal Type II and III [Go to Page]
- 5.15.1 Test apparatus
- 5.15.2 Test sample
- 5.15.3 Measuring parameters
- 5.15.4 Test condition
- 5.15.5 Test procedure
- 5.15.6 Test result
- Annex A (informative)Recommended test sequence
- Annex B (normative)Basic test structure
- Annex C (normative)Method of measuring the hot gas temperature
- Annex D (informative)Example of a test report
- Annex E (informative)Terminals [Go to Page]
- E.1 Characterization of a terminal [Go to Page]
- E.1.1 Types of terminals [Go to Page]
- E.1.1.1 Type I
- E.1.1.2 Type II
- E.1.1.3 Type III
- E.1.2 Wind direction characteristics
- E.2 Requirements [Go to Page]
- E.2.1 General
- E.2.2 Flow resistance of terminals Type I, II and III
- E.2.3 Aerodynamic properties of terminals Type II and III [Go to Page]
- E.2.3.1 Terminal Type II
- E.2.3.2 Terminal Type III
- E.2.4 Rain water ingress
- E.2.5 Icing behaviour
- Annex F (informative)Type of test structure [Go to Page]