Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
2022 California Residential Code Approved Express Terms 05/21 - SFM, 2022
- APPROVED BY THE CALIFORNIA BUILDING STANDARDS COMMISSION JANUARY 19, 2022
- FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE STATE FIRE MARSHAL REGARDING THE 2022 CALIFORNIA RESIDENTIAL CODE,
- CALIFORNIA CODE OF REGULATIONS, TITLE 24, PART 2.5
- (SFM 05/21) [Go to Page]
- LEGEND for EXPRESS TERMS (Based on model codes - Parts 2, 2.5, 3, 4, 5, 9, 10)
- 45-DAY EXPRESS TERMS [Go to Page]
- Item 1-1 Chapter 1, Administration, Division I, California Administration, Section 1.1.0 General through 1.1.12
- Item 1-2 Chapter 1, Administration, Division I, California Administration, Section 1.1.1 Title
- Item 1-3 Chapter 1, Administration, Division I, California Administration, Section 1.11. through 1.11.11
- Item 1-4 Chapter 1, Administration, Division I, California Administration, Section 1.11.1 SFM-Office of the State Fire Marshal
- Item 1-5 Chapter 1, Administration, Division I, California Administration, Section 1.11.4.4 Fire Clearance Preinspection
- Item 1-6 Chapter 1, Administration, Division I, California Administration, Section 1.11.4.5 Care Facilities
- Item 1-7 Chapter 1, Administration, Division I, California Administration, Section 1.11.11 Adopting Agency Identification
- Item 1-8 Chapter 1, Scope and Administration, Division II
- Item 1-9 Chapter 1, Scope and Administration, Division II, User Note
- Item 1-10 Chapter 1, Administration, Division II, Administration
- Item 1-11 Chapter 1, Administration, Division II, Administration
- Item 2-1 Chapter 2, Definitions
- Item 2-2 Chapter 2, Section R202 General Definitions, Child Care
- Item 2-3 Chapter 2, Section R202 General Definitions, Day-Care
- Item 2-4 Chapter 2, Definitions, Energy Storage Systems
- Item 2-5 Chapter 2, Definitions, Exterior Wall Assemby
- Item 2-6 Chapter 2, Definitions, Exterior Wall Covering
- Item 2-7 Chapter 2, Section R202 General Definitions, Inflatable Amusement Device
- Item 2-8 Chapter 2, Section R202 General Definitions, Large-Scale Fire Testing
- Item 2-9 Chapter 2, Section R202 General Definitions, Photovoltaic (PV) Panel System, Ground-Mounted
- Item 2-10 Chapter 2, Section R202 General Definitions, Photovoltaic (PV) Support Structure Elevated
- Item 2-11 Chapter 2, Section R202 General Definitions, Toddler
- Item 2-12 Chapter 2, Section R202 General Definitions, WILDLAND-URBAN INTERFACE (WUI)
- Item 3-1 Chapter 3, Building Planning
- Item 3-2 Chapter 3, Building Planning, Section R302
- Item 3-3 Chapter 3, Building Planning, Section R310 Emergency Escape and Rescue Openings
- Item 3-4 Chapter 3, Building Planning, Section R324 Solar Energy Systems
- Item 3-5 Chapter 3, Building Planning, Section R324 Solar Energy Systems
- Item 3-6 Chapter 3, Building Planning, Section R325 Mezzanines
- Item 3-7 Chapter 3, Building Planning, Section R326 Habitable Attics
- Item 3-8 Chapter 3, Building Planning, Section R328 Energy Storage Systems
- Item 3-9 Chapter 3, Building Planning, Section R336 Large Family Day Care Homes
- Item 3-10 Chapter 3, Building Planning, Section R337 Materials and Construction methods for Exterior Wildfire Exposure
- Item 4-1 Chapter 4, Foundations
- Item 5-1 Chapter 5, Floors
- Item 6-1 Chapter 6, Wall Construction
- Item 7-1 Chapter 7, Wall Covering
- Item 8-1 Chapter 8, Roof-Ceiling Construction
- Item 8-2 Chapter 8, Roof-Ceiling Construction
- Item 9-1 Chapter 9, Roof Assemblies
- Item 9-2 Chapter 9, Roof Assemblies
- Item 9-3 Chapter 9, Roof Assemblies
- Item 9-4 Chapter 9, Roof Assemblies
- Item 10-1 Chapter 10, Chimneys and Fireplaces
- Item 12-1 Chapter 12, Mechanical Administration
- Item 13-1 Chapter 13, General Mechanical System Requirements
- Item 14-1 Chapter 14, Heating And Cooling Equipment And Appliances
- Item 15-1 Chapter 15, Exhaust Systems
- Item 16-1 Chapter 16, Duct Systems
- Item 17-1 Chapter 17, Combustion Air
- Item 18-1 Chapter 18, Chimneys And Vents
- Item 19-1 Chapter 19, Special Appliances, Equipment And Systems
- Item 20-1 Chapter 20, Boilers And Water Heaters
- Item 21-1 Chapter 21, Hydronic Piping
- Item 22-1 Chapter 22, Special Piping And Storage Systems
- Item 23-1 Chapter 23, Solar Thermal Energy Systems
- Item 24-1 Chapter 24, Fuel Gas
- Item 25-1 Chapter 25, Plumbing Administration
- Item 26-1 Chapter 26, General Plumbing Requirements
- Item 27-1 Chapter 27, Plumbing Fixtures
- Item 28-1 Chapter 28, Water Heaters
- Item 29-1 Chapter 29, Water Supply And Distribution
- Item 30-1 Chapter 30, Sanitary Drainage
- Item 31-1 Chapter 31, Vents
- Item 32-1 Chapter 32, Traps
- Item 33-1 Chapter 33, Storm Drainage
- Item 34-1 Chapter 34, Storm Drainage
- Item 35-1 Chapter 35, Electrical Definitions
- Item 36-1 Chapter 36, Services
- Item 37-1 Chapter 37, Branch Circuit And Feeder Requirements
- Item 38-1 Chapter 38, Wiring Methods
- Item 39-1 Chapter 39, Power And Lighting Distribution
- Item 40-1 Chapter 40, Devices And Luminaires
- Item 41-1 Chapter 41, Appliance Installation
- Item 42-1 Chapter 42, Appliance Installation
- Item 43-1 Chapter 43, Class 2 Remote-Control, Signaling And Power-Limited Circuits
- Item 44-1 Chapter 44, Referenced Standards
- Item 44-2 Chapter 44, Referenced Standards, ASTM F2374 Standard Practice For Design, Manufacture, Operation, and Maintenance Of Inflatable Amusement Devices
- Item 44-2.1 Chapter 44, Referenced Standards, SFM 12-7A-5 Ignition Resistant Building Material
- Item 44-3 Chapter 44, NFPA 13 Installation of Sprinkler Systems
- Item 44-4 Chapter 44, NFPA 13D Installation of Sprinkler Systems
- Item 44-5 Chapter 44, NFPA 13R Standard for the Installation of Sprinkler Systems in Low-rise Residential Occupancies
- Item 44-6 Chapter 44, NFPA 70 National Electrical Code
- Item 44-7 Chapter 44, NFPA 72 National Fire Alarm and Signaling Code, as amended*
- Item 44-8 Chapter 44, Referenced Standards, SFM 12-7A-5 Ignition Resistant Building Material
- Item 44-9 Chapter 44, Referenced Standards, UL 9540 Standard for Energy Storage Systems and Equipment
- Item 44-10 Chapter 44, Referenced Standards, UL 9540A Standard for Safety Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems
- Item A-1 Appendices, Appendix AA-AE, Reserved
- Item A-2 Appendices, Appendix AF, Radon Control Methods
- Item A-3 Appendices, Appendix AG, Reserved
- Item A-4 Appendices, Appendix AH, Patio Covers
- Item A-5 Appendices, Appendix AJ, Existing Buildings and Structures
- Item A-6 Appendices, Appendix AK, Sound Transmission
- Item A-7 Appendices, Appendix AL, Permit Fees
- Item A-8 Appendices, Appendix AM-AN, Reserved
- Item A-9 Appendices, Appendix AO, Automatic Vehicular Gates
- Item A-10 Appendices, Appendix AP, Reserved
- Item A-11 Appendices, Appendix AQ, Tiny Houses
- Item A-11.1 Appendices, Appendix AR, Light Straw-Clay Construction
- Item A-12 Appendices, Appendix AT, Solar Ready Provisions-Detached one- and Two-Family Dwellings and Townhouses
- Item A-13 Appendices, Appendix AU, Reserved
- Item A-14 Appendices, Appendix AV, Board of Appeals
- Item A-14.1 Appendices, Appendix AW, 3-D -PRINTED Building Construction
- Item A-15 Appendices, Appendix AX, Swimming Pool Safety Act
- Item A-16 Appendices, Appendix AY, Areas Protected by The Facilities of the Central Valley Flood Protection Plan
- Item A-17 Appendices, Appendix AZ, Emergency Housing [Go to Page]