BS EN 62485-3:2014 Safety requirements for secondary batteries and battery installations - Traction batteries, 2014
- EN62485-3{2014}e.pdf [Go to Page]
- Foreword
- Endorsement notice
- Annex ZA (normative) Normative references to international publications with their corresponding European publications
- 30315742-VOR.pdf [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Protection against electric shock by the battery and charger [Go to Page]
- 4.1 General
- 4.2 Protection against both direct and indirect contact
- 4.3 Protection against direct and indirect contact when discharging the traction battery on the vehicle (battery disconnected from charger/mains)
- 4.4 Protection against direct and indirect contact when charging the traction battery
- 5 Prevention of short circuits and protection from other effects of electric current [Go to Page]
- 5.1 Cables and cell connectors
- 5.2 Protective measures during maintenance
- 5.3 Battery insulation
- 6 Provisions against explosion hazards by ventilation [Go to Page]
- 6.1 Gas generation
- 6.2 Ventilation requirements [Go to Page]
- 6.2.1 General
- 6.2.2 Calculation of the minimum ventilation air flow
- 6.2.3 Recommended charging practice
- 6.2.4 Special chargers
- 6.2.5 Multiple charging
- 6.3 Natural ventilation
- 6.4 Forced ventilation
- 6.5 Close vicinity to the battery
- 6.6 Ventilation of battery compartment
- 7 Provisions against electrolyte hazard [Go to Page]
- 7.1 Electrolyte and water
- 7.2 Protective clothing
- 7.3 Accidental contact, "first aid" [Go to Page]
- 7.3.1 General
- 7.3.2 Eye contact
- 7.3.3 Skin contact
- 7.4 Battery accessories and maintenance tools
- 8 Battery containers and enclosures
- 9 Accommodation for charging/maintenance
- 10 Battery peripheral equipment/accessories [Go to Page]
- 10.1 Battery monitoring system
- 10.2 Central water filling system [Go to Page]
- 10.2.1 General
- 10.2.2 Safety aspects
- 10.3 Central degassing systems
- 10.4 Thermal management systems
- 10.5 Electrolyte agitation system
- 10.6 Catalyst vent plugs
- 10.7 Connectors (plugs/sockets)
- 11 Identification labels, warning notices and instructions for use, installation and maintenance [Go to Page]
- 11.1 Warning labels
- 11.2 Identification label
- 11.3 Instructions
- 11.4 Other labels
- 12 Transportation, storage, disposal and environmental aspects [Go to Page]
- 12.1 Packing and transport
- 12.2 Disassembly, disposal, and recycling of batteries
- 13 Inspection and monitoring
- Bibliography
- Table 1 – Guideline: Maximum final charging current in A per 100 Ahduring normal conditions of use
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Protection contre les chocs électriques par la batterie et le chargeur [Go to Page]
- 4.1 Généralités
- 4.2 Protection contre à la fois les contacts directs et indirects
- 4.3 Protection contre les contacts directs et indirects pendant la décharge de la batterie de traction sur le véhicule (batterie déconnectée du chargeur/du réseau)
- 4.4 Protection contre les contacts directs et indirects pendant la charge de la batterie de traction
- 5 Prévention des courts-circuits et protection contre les autres effets du courant électrique [Go to Page]
- 5.1 Câbles et connecteurs d’éléments
- 5.2 Mesures de protection pendant la maintenance
- 5.3 Isolation des batteries
- 6 Dispositions contre les dangers d’explosion par ventilation [Go to Page]
- 6.1 Émission de gaz
- 6.2 Exigences de ventilation [Go to Page]
- 6.2.1 Généralités
- 6.2.2 Calcul du débit d'air de ventilation minimum
- 6.2.3 Pratiques de charge recommandées
- 6.2.4 Chargeurs spéciaux
- 6.2.5 Charge multiple
- 6.3 Ventilation naturelle
- 6.4 Ventilation forcée
- 6.5 Proximité d’une batterie
- 6.6 Ventilation du compartiment de batterie
- 7 Dispositions contre les dangers liés à l’électrolyte [Go to Page]
- 7.1 Électrolyte et eau
- 7.2 Vêtements de protection
- 7.3 Contact accidentel, "premier secours" [Go to Page]
- 7.3.1 Généralités
- 7.3.2 Contact avec les yeux
- 7.3.3 Contact avec la peau
- 7.4 Accessoires de batteries et outils de maintenance
- 8 Bacs et enveloppes pour batteries
- 9 Emplacement pour charge / maintenance
- 10 Équipements périphériques et accessoires de batteries [Go to Page]
- 10.1 Système de surveillance de la batterie
- 10.2 Système central de remplissage d’eau [Go to Page]
- 10.2.1 Généralités
- 10.2.2 Aspects de sécurité
- 10.3 Systèmes centraux de dégazage
- 10.4 Systèmes de gestion thermique
- 10.5 Système d’agitation d’électrolyte
- 10.6 Bouchons catalyseurs
- 10.7 Connecteurs (fiches/socles)
- 11 Étiquettes d’identification, avertissements et instructions pour l’utilisation, l’installation et la maintenance [Go to Page]
- 11.1 Étiquettes d’avertissement
- 11.2 Étiquette d’identification
- 11.3 Instructions
- 11.4 Autres étiquettes
- 12 Transport, stockage, mise au rebut et aspects d’environnement [Go to Page]
- 12.1 Emballage et transport
- 12.2 Démontage, mise au rebut et recyclage des batteries
- 13 Contrôle et surveillance
- Bibliographie
- Tableau 1 – Lignes directrice: Courant de charge final maximumen A pour 100 Ah dans des conditions normales d'utilisation [Go to Page]