Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
PD IEC/TR 62778:2014 Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires, 2014
- 30304759-VOR.pdf [Go to Page]
- CONTENTS
- FOREWORD
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General
- 5 Spectrum, colour temperature, and blue light hazard [Go to Page]
- 5.1 Calculation of blue light hazard quantities and photometric quantities from emission spectra
- 5.2 Luminance and illuminance regimes that give rise to tmax values below 100 s
- 6 LED packages, LED modules, lamps and luminaires
- 7 Measurement information flow [Go to Page]
- 7.1 Basic flow
- 7.2 Conditions for the radiance measurement
- 7.3 Special cases (I): Replacement by a lamp or LED module of another type
- 7.4 Special cases (II): Arrays and clusters of primary light sources
- 8 Risk group classification
- Annex A (informative) Geometrical relations between radiance, irradiance and radiant intensity
- Annex B (informative) Distance dependence of tmax for a certain light source
- Annex C (informative) Summary of recommendations to assist the consistent application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires [Go to Page]
- C.1 General
- C.2 Situation of RG0 or RG1 classification not requiring radiance or irradiance measurement [Go to Page]
- C.2.1 Boundary conditions
- C.2.2 True luminance values giving risk group not greater than RG1
- C.2.3 Illuminance values giving risk group not greater than RG1
- C.3 Situation for the classification of light sources larger than 2,2 mm and luminaires using these light sources
- C.4 Situation for the classification of light sources smaller than 2,2 mm and luminaires using these light sources
- C.5 Situation for the classification of light sources that pose practical difficulties in measurements at 200 mm
- Annex D (informative) Detailed assessment of arrays and clusters of primary light sources, comprised of LED packages [Go to Page]
- D.1 General
- D.2 Approach [Go to Page]
- D.2.1 Step by step assessment
- D.2.2 Type of arrays and additional steps
- D.2.3 Complete flowchart
- D.3 Derivation of the formula for average radiance of the full array
- Bibliography
- Figures [Go to Page]
- Figure 1 – Blue light hazard efficacy of luminous radiation, KB,v, for a range of light sources from different technologies, and for a few typical daylight spectra
- Figure 2 – Comparison between the curves involved in calculating KB,v (the photopic eye sensitivity curve and the blue light spectral weighting function) and the CIE 1931 Y and Z curves involved in calculating the CIE 1931 x, y colour coordinates
- Figure 3 – Correlation plot between the quantity (1 – x – y)/y,
calculated from the CIE 1931 x, y colour coordinates, and the
value of KB,v, for all the spectra analysed to generate Figure 1
- Figure 4 – Estimate of the luminance level where LB = 10 000 W/(m2.sr),
border between RG1 (tmax > 100 s) and RG2 (tmax < 100 s) in the
large source regime, as a function of CCT
- Figure 5 – Estimate of the illuminance level where EB = 1 W/m2,
border between RG1 (tmax > 100 s) and RG2 (tmax < 100 s)
in the small source regime, as a function of CCT
- Figure 6 – Relation of illuminance E, distance d and intensity I
- Figure 7 – Flow chart from the primary light source (in blue) to the luminaire based on this light source (in amber)
- Figure A.1 – Schematic image of the situation considered in Annex A
- Figure B.1 – General appearance of tmax as a function of viewing distance d, for any light source with homogeneous luminance L and diameter D
- Figure C.1 – Luminance values from Table C.1 in relation to the RG1/RG2 border as function of correlated colour temperature
- Figure C.2 – Illuminance values from Table C.2 in relation to the RG1/RG2 border as function of correlated colour temperature
- Figure D.1 – Examples of secondary lenses with identical light distribution and alignment
- Figure D.2 – Examples of LED arrays with bare LED packages
- Figure D.3 – Evaluation whether one or more LED elements fall in 11 mrad field of view at distance d1
- Figure D.4 – Complete flowchart of the detailed assessment of arrays and clusters of primary light sources
- Tables [Go to Page]
- Table 1 – Correlation between exposure time and risk group
- Table C.1 – Luminance values giving risk group not greater than RG1
- Table C.2 – Illuminance values giving risk group not greater than RG1
- Table D.1 – Applicability of steps 1 to 6 [Go to Page]